Your browser doesn't support javascript.
loading
Subcomponent self-assembly construction of tetrahedral cage FeII4L4 for high-resolution gas chromatographic separation.
Luo, Zong-Hong; Zhu, Yu-Lan; Ran, Xiao-Yan; Ma, An-Xu; Zhang, Yue; Zhou, Hong-Mei; Wang, Bang-Jin; Zhang, Jun-Hui; Xie, Sheng-Ming; Yuan, Li-Ming.
Affiliation
  • Luo ZH; Department of Chemistry, Yunnan Normal University, Kunming, 650500, PR China.
  • Zhu YL; Department of Chemistry, Yunnan Normal University, Kunming, 650500, PR China.
  • Ran XY; Department of Chemistry, Yunnan Normal University, Kunming, 650500, PR China.
  • Ma AX; Department of Chemistry, Yunnan Normal University, Kunming, 650500, PR China.
  • Zhang Y; Department of Chemistry, Yunnan Normal University, Kunming, 650500, PR China.
  • Zhou HM; Department of Chemistry, Yunnan Normal University, Kunming, 650500, PR China.
  • Wang BJ; Department of Chemistry, Yunnan Normal University, Kunming, 650500, PR China.
  • Zhang JH; Department of Chemistry, Yunnan Normal University, Kunming, 650500, PR China.
  • Xie SM; Department of Chemistry, Yunnan Normal University, Kunming, 650500, PR China. Electronic address: xieshengming_2006@163.com.
  • Yuan LM; Department of Chemistry, Yunnan Normal University, Kunming, 650500, PR China.
Talanta ; 277: 126388, 2024 Sep 01.
Article in En | MEDLINE | ID: mdl-38870759
ABSTRACT
Metal organic cages (MOCs), as an emerging discrete supramolecular compounds, have received widespread attention in separation, biomedicine, gas capture, catalysis, and molecular recognition due to their porosity, adjustability and stability. Herein, we present a new chiral MOC FeII4L4 coated capillary column prepared for gas chromatographic (GC) separation of different types of organic compounds, including n-alkanes, n-alcohols, alkylbenzenes, isomers, especially for racemic compounds. There are 20 different kinds of racemates (e.g., alcohols, ethers, epoxides, esters, alkenes, and aldehydes) were well resolved on the FeII4L4 chiral column and a maximum resolution value for 1-phenyl-1-propanol reaches 6.17. The FeII4L4 coated column exhibited high column efficiency (3100 plates m-1 for n-dodecane) and good enantiomeric resolution complementary to that of a commercial ß-DEX 120 column and the previously reported chiral MOC [Fe4L6] (ClO4)8 coated column. The relative standard deviation (RSDs) of the peak area and retention time of glycidol and nitrotoluene were below 1.2 %. This study reveals that chiral MOCs have good application prospects in chromatographic separation.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Talanta Year: 2024 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Talanta Year: 2024 Document type: Article