Your browser doesn't support javascript.
loading
Biomonitoring urinary organophosphorus flame retardant metabolites by liquid-liquid extraction and ultra-high performance liquid chromatography-tandem mass spectrometry and their association with oxidative stress.
Li, Yongxian; Dai, Yingyi; Luo, Xinni; Zhang, Lin; Yuan, Jun; Tan, Lei.
Affiliation
  • Li Y; Guangzhou Center for Disease Control and Prevention, Guangzhou, 510440, China.
  • Dai Y; Guangzhou Center for Disease Control and Prevention, Guangzhou, 510440, China.
  • Luo X; School of Public Health, Southern Medical University, Guangzhou, 510515, China.
  • Zhang L; Affiliated Brain Hospital of Guangzhou Medical University, Guangzhou, 510370, China.
  • Yuan J; Guangzhou Center for Disease Control and Prevention, Guangzhou, 510440, China.
  • Tan L; Guangzhou Center for Disease Control and Prevention, Guangzhou, 510440, China.
Anal Bioanal Chem ; 416(20): 4543-4554, 2024 Aug.
Article in En | MEDLINE | ID: mdl-38877147
ABSTRACT
Organophosphate flame retardants (OPFRs) are widely used as substitutes for traditional brominated flame retardants, necessitating a reliable and sensitive method for biomonitoring their urinary metabolites to assess human exposure. This study conducted biomonitoring of 10 metabolites of OPFRs in 152 adults and assessed their association with oxidative stress biomarkers 8-hydroxydeoxyguanosine and 8-hydroxyguanosine. Urinary metabolites of OPFRs were released via enzymatic deconjugation. The addition of sodium chloride to the urine samples increases the ionic strength, inducing a salting-out effect that reduces the solubility of these compounds, thereby facilitating their extraction with a mixture of ethyl acetate and acetonitrile. Then, the metabolites of OPFRs were quantified by ultra-high performance liquid chromatography-tandem mass spectrometry, and we validated the method for linear range, precision, matrix effect, and method detection limit. The detection limit of the metabolites of OPFRs ranged from 0.01 to 0.2 µg/L, and these metabolites were detected with high frequencies ranging from 25.0 to 98.68% in the urine samples. The concentration of bis (2-chloroethyl) phosphate was significantly higher in males than in females, with the geometric mean concentration of 0.88 µg/L for males and 0.53 µg/L for females, respectively. Spearman correlation analysis revealed weak but statistically significant positive correlations among the urinary metabolites. Bayesian kernel machine regression analysis showed a significant positive association between elevated urinary concentrations of metabolites of OPFRs and increased oxidative stress levels. Di-n-butyl phosphate was identified as the metabolite that significantly contributed to the elevated level of 8-hydroxyguanosine.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Organophosphorus Compounds / Oxidative Stress / Tandem Mass Spectrometry / Limit of Detection / Liquid-Liquid Extraction / Flame Retardants / Biological Monitoring Limits: Adult / Female / Humans / Male / Middle aged Language: En Journal: Anal Bioanal Chem Year: 2024 Document type: Article Affiliation country: China

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Organophosphorus Compounds / Oxidative Stress / Tandem Mass Spectrometry / Limit of Detection / Liquid-Liquid Extraction / Flame Retardants / Biological Monitoring Limits: Adult / Female / Humans / Male / Middle aged Language: En Journal: Anal Bioanal Chem Year: 2024 Document type: Article Affiliation country: China