Your browser doesn't support javascript.
loading
Establishment of a Nucleic Acid Detection Method for Norovirus GII.2 Genotype Based on RT-RPA and CRISPR/Cas12a-LFS.
Wang, Ting; Zeng, Hao; Kang, Jie; Lei, Lanlan; Liu, Jing; Zheng, Yuhong; Qian, Weidong; Fan, Cheng.
Affiliation
  • Wang T; School of Biomedical and Pharmaceutical Sciences, Shaanxi University of Science and Technology, Xian, China.
  • Zeng H; School of Biomedical and Pharmaceutical Sciences, Shaanxi University of Science and Technology, Xian, China.
  • Kang J; Shaanxi Institute of Supervision and Testing on Product Quality, Xian, China.
  • Lei L; Shaanxi Institute of Supervision and Testing on Product Quality, Xian, China.
  • Liu J; Shaanxi Institute of Supervision and Testing on Product Quality, Xian, China.
  • Zheng Y; Shaanxi Institute of Supervision and Testing on Product Quality, Xian, China.
  • Qian W; School of Biomedical and Pharmaceutical Sciences, Shaanxi University of Science and Technology, Xian, China.
  • Fan C; Shaanxi Institute of Supervision and Testing on Product Quality, Xian, China.
Pol J Microbiol ; 73(2): 253-262, 2024 Jun 01.
Article in En | MEDLINE | ID: mdl-38905280
ABSTRACT
To establish a rapid detection method for norovirus GII.2 genotype, this study employed reverse transcription recombinase polymerase amplification (RT-RPA) combined with CRISPR/Cas12a and lateral flow strip (RT-RPA-Cas12a-LFS). Here, the genome of norovirus GII.2 genotype was compared to identify highly conserved sequences, facilitating the design of RT-RPA primers and crRNA specific to the conserved regions of norovirus GII.2. Subsequently, the reaction parameters of RT-RPA were optimized and evaluated using agar-gel electrophoresis and LFS. The results indicate that the conserved sequences of norovirus GII.2 were successfully amplified through RT-RPA at 37°C for 25 minutes. Additionally, CRISPR/Cas12a-mediated cleavage detection was achieved through LFS at 37°C within 10 minutes using the amplification products as templates. Including the isothermal amplification reaction time, the total time is 35 minutes. The established RT-RPA-Cas12a-LFS method demonstrated specific detection of norovirus GII.2, yielding negative results for other viral genomes, and exhibited an excellent detection limit of 10 copies/µl. The RT-RPA-Cas12a-LFS method was further compared with qRT-PCR by analyzing 60 food-contaminated samples. The positive conformity rate was 100%, the negative conformity rate was 95.45%, and the overall conformity rate reached 98.33%. This detection method for norovirus GII.2 genotype is cost-effective, highly sensitive, specific, and easy to operate, offering a promising technical solution for field-based detection of the norovirus GII.2 genotype.