Your browser doesn't support javascript.
loading
Elucidating the Gas-Phase Behavior of Nitazene Analog Protomers Using Structures for Lossless Ion Manipulations Ion Mobility-Orbitrap Mass Spectrometry.
Hollerbach, Adam L; Lin, Vivian S; Ibrahim, Yehia M; Ewing, Robert G; Metz, Thomas O; Rodda, Kabrena E.
Affiliation
  • Hollerbach AL; Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States.
  • Lin VS; Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States.
  • Ibrahim YM; Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States.
  • Ewing RG; Nuclear, Chemistry & Biology Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States.
  • Metz TO; Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States.
  • Rodda KE; Nuclear, Chemistry & Biology Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States.
J Am Soc Mass Spectrom ; 35(7): 1609-1621, 2024 Jul 03.
Article in En | MEDLINE | ID: mdl-38907730
ABSTRACT
2-Benzylbenzimidazoles, or "nitazenes", are a class of novel synthetic opioids (NSOs) that are increasingly being detected alongside fentanyl analogs and other opioids in drug overdose cases. Nitazenes can be 20× more potent than fentanyl but are not routinely tested for during postmortem or clinical toxicology drug screens; thus, their prevalence in drug overdose cases may be under-reported. Traditional analytical workflows utilizing liquid chromatography-tandem mass spectrometry (LC-MS/MS) often require additional confirmation with authentic reference standards to identify a novel nitazene. However, additional analytical measurements with ion mobility spectrometry (IMS) may provide a path toward reference-free identification, which would greatly accelerate NSO identification rates in toxicology laboratories. Presented here are the first IMS and collision cross section (CCS) measurements on a set of fourteen nitazene analogs using a structures for lossless ion manipulations (SLIM)-orbitrap MS. All nitazenes exhibited two high intensity baseline-separated IMS distributions, which fentanyls and other drug and druglike compounds also exhibit. Incorporating water into the electrospray ionization (ESI) solution caused the intensities of the higher mobility IMS distributions to increase and the intensities of the lower mobility IMS distributions to decrease. Nitazenes lacking a nitro group at the R1 position exhibited the greatest shifts in signal intensities due to water. Furthermore, IMS-MS/MS experiments showed that the higher mobility IMS distributions of all nitazenes possessing a triethylamine group produced fragment ions with m/z 72, 100, and other low intensity fragments while the lower mobility IMS distributions only produced fragment ions with m/z 72 and 100. The IMS, solvent, and fragmentation studies provide experimental evidence that nitazenes potentially exhibit three gas-phase protomers. The cyclic IMS capability of SLIM was also employed to partially resolve four sets of structurally similar nitazene isomers (e.g., protonitazene/isotonitazene, butonitazene/isobutonitazene/secbutonitazene), showcasing the potential of using high-resolution IMS separations in MS-based workflows for reference-free identification of emerging nitazenes and other NSOs.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Ion Mobility Spectrometry Language: En Journal: J Am Soc Mass Spectrom Year: 2024 Document type: Article Affiliation country: Estados Unidos

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Ion Mobility Spectrometry Language: En Journal: J Am Soc Mass Spectrom Year: 2024 Document type: Article Affiliation country: Estados Unidos