Your browser doesn't support javascript.
loading
Facial tightening using a novel vacuum-assisted microneedle fractional radiofrequency system: A prospective, randomized, split-face study.
Liu, Ying; Yu, Wenxin; Zhu, Jiafang; Cen, Qingqing; Zhou, Lucia; Ma, Gang; Shang, Ying; Han, Yue; Lin, Xiaoxi.
Affiliation
  • Liu Y; Department of Laser and Aesthetic Medicine, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Yu W; Department of Plastic and Aesthetic Surgery, Nanfang Hospital, Southern Medical University, Guangzhou, China.
  • Zhu J; Department of Laser and Aesthetic Medicine, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Cen Q; Department of Plastic and Reconstructive Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Zhou L; Department of Laser and Aesthetic Medicine, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Ma G; Department of Laser and Aesthetic Medicine, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Shang Y; Department of Plastic and Reconstructive Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Han Y; Department of Laser and Aesthetic Medicine, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Lin X; Department of Plastic and Reconstructive Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
J Cosmet Dermatol ; 2024 Jun 24.
Article in En | MEDLINE | ID: mdl-38923679
ABSTRACT

BACKGROUND:

The microneedle fractional radiofrequency system (MFRS) is able to rejuvenate facial appearance by heating and coagulating certain depth of skin tissue.

OBJECTIVE:

To evaluate the safety and efficacy of a novel vacuum-assisted MFRS for facial contour tightening.

METHODS:

This prospective, randomized, split-face study included 21 patients who underwent three treatments with a vacuum-assisted MFRS at 1-month intervals. Half of the face was treated with the MFRS; the other half was untreated (control). Facial volume changes and wrinkles were objectively measured using a three-dimensional imaging system and VISIA-CR.

RESULTS:

Volume changes of the treated midface were -0.24 ± 0.75, -0.59 ± 0.92, and -0.55 ± 0.65 mL at 1, 3, 6 months follow-up; however, measurements of the control side were 0.08 ± 0.70, -0.08 ± 0.53, and - 0.10 ± 0.86 mL, indicating significant reductions (p < 0.05). The number of facial wrinkles on the treated side was significantly reduced to 12.44 ± 4.85 at 3 months and sustained at 6 months (11.11 ± 4.100) compared to the control side (14.89 ± 5.26 and 13.22 ± 4.44, respectively; p < 0.05). No long-term side effects occurred.

CONCLUSION:

The vacuum-assisted MFRS is safe and effective and is recommended for improving facial tightening and reducing wrinkles. This technology is sufficient to ensure the insertion depth, thus helping to improve the treatment accuracy and safety. The MFRS provides sustained effects for at least 6 months.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Cosmet Dermatol Journal subject: DERMATOLOGIA Year: 2024 Document type: Article Affiliation country: China

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Cosmet Dermatol Journal subject: DERMATOLOGIA Year: 2024 Document type: Article Affiliation country: China