Your browser doesn't support javascript.
loading
Compact Numerical Aperture 0.5 Fiber Optic Spectrometer Design Using Active Image Plane Tilt.
Yue, Pinliang; Yang, Mingyu; Jiao, Qingbin; Xu, Liang; Wang, Xiaoxu; Zhang, Mingle; Tan, Xin.
Affiliation
  • Yue P; Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
  • Yang M; University of Chinese Academy of Sciences, Beijing 100049, China.
  • Jiao Q; Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
  • Xu L; Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
  • Wang X; Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
  • Zhang M; Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
  • Tan X; Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
Sensors (Basel) ; 24(12)2024 Jun 15.
Article in En | MEDLINE | ID: mdl-38931666
ABSTRACT
The numerical aperture of the spectrometer is crucial for weak signal detection. The transmission lens-based configuration has more optimization variations, and the grating can work approximately in the Littrow condition; thus, it is easier to acquire high numerical aperture (NA). However, designing a large aperture focusing lens remains challenging, and thus, ultra-high NA spectrometers are still difficult to acquire. In this paper, we propose a method of setting image plane tilt ahead directly when designing the large aperture focusing lens to simplify the high NA spectrometer design. By analyzing the accurate demands of the focusing lens, it can be concluded that a focusing lens with image plane tilt has much weaker demand for achromatism, and other monochromatic aberration can also be reduced, which is helpful to increase the NA. An NA0.5 fiber optic spectrometer design is given to demonstrate the proposed method. The design results show that the NA can achieve 0.5 using four lenses of two materials, and the MTF is higher than 0.5 when the spectral dispersion length is 12.5 mm and the pixel size is 25 µm, and thus, the spectral resolution can achieve 6.5 nm when the spectral sampling ratio is 21. The proposed method can provide reference for applications when appropriate materials are limited and high sensitivity is necessary.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Sensors (Basel) Year: 2024 Document type: Article Affiliation country: China

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Sensors (Basel) Year: 2024 Document type: Article Affiliation country: China