Your browser doesn't support javascript.
loading
Exploring the Feasibility of Estimating Intraocular Pressure Using Vibrational Response of the Eye: A Methodological Approach.
Jeon, Seongwook; Toh, Gyungmin; Park, Junhong; Lee, Won June.
Affiliation
  • Jeon S; Department of Mechanical Engineering, Hanyang University, Seoul 04763, Republic of Korea.
  • Toh G; Department of Mechanical Engineering, Hanyang University, Seoul 04763, Republic of Korea.
  • Park J; Department of Mechanical Engineering, Hanyang University, Seoul 04763, Republic of Korea.
  • Lee WJ; Department of Ophthalmology, Hanyang University College of Medicine, Seoul 04763, Republic of Korea.
Sensors (Basel) ; 24(12)2024 Jun 20.
Article in En | MEDLINE | ID: mdl-38931781
ABSTRACT
This study addresses the limitations of current tonometry techniques by exploring vibroacoustic properties for estimating intraocular pressure (IOP), a key diagnostic parameter for monitoring glaucoma-a significant risk factor for vision loss. Utilizing vivo porcine eyeballs, we investigated the relationship between IOP and the nonlinear vibration transfer function ratio (NVTFR). Through applying varying vibration levels and analyzing responses with transfer function analysis and univariate regression, we identified a strong negative correlation between NVTFR and IOP, evidenced by a Pearson correlation coefficient of -0.8111 and significant results from generalized linear model (GLM) regression (p-value < 0.001). These findings indicate the potential of NVTFR as a vital indicator of IOP changes. Our study highlights the feasibility of using vibroacoustic properties, specifically NVTFR, to measure IOP. While further refinement is necessary for in vivo application, this approach opens new possibilities for non-invasive and patient-friendly IOP monitoring, potentially enhancing ophthalmology diagnostic techniques and providing a foundation for future research and development in this critical area.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Tonometry, Ocular / Vibration / Intraocular Pressure Limits: Animals / Humans Language: En Journal: Sensors (Basel) Year: 2024 Document type: Article Country of publication: Suiza

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Tonometry, Ocular / Vibration / Intraocular Pressure Limits: Animals / Humans Language: En Journal: Sensors (Basel) Year: 2024 Document type: Article Country of publication: Suiza