Your browser doesn't support javascript.
loading
A novel method for determining dose distribution on panoramic reconstruction computed tomography images from radiotherapy computed tomography.
Okamoto, Hiroyuki; Sakuramachi, Madoka; Yatsuoka, Wakako; Ueno, Takao; Katsura, Kouji; Murakami, Naoya; Nakamura, Satoshi; Iijima, Kotaro; Chiba, Takahito; Nakayama, Hiroki; Shuto, Yasunori; Takano, Yuki; Kobayashi, Yuta; Kishida, Hironori; Urago, Yuka; Nishitani, Masato; Nishina, Shuka; Arai, Koushin; Igaki, Hiroshi.
Affiliation
  • Okamoto H; Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, Tokyo, Japan.
  • Sakuramachi M; Department of Radiation Oncology, National Cancer Center Hospital, Tokyo, Japan.
  • Yatsuoka W; Dental Division, National Cancer Center Hospital, Tokyo, Japan.
  • Ueno T; Dental Division, National Cancer Center Hospital, Tokyo, Japan.
  • Katsura K; Department of Oral Radiology, Niigata University Medical and Dental Hospital, Niigata, Japan.
  • Murakami N; Department of Radiology, Juntendo University, Tokyo, Japan.
  • Nakamura S; Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, Tokyo, Japan.
  • Iijima K; Department of Radiology, Juntendo University, Tokyo, Japan.
  • Chiba T; Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, Tokyo, Japan.
  • Nakayama H; Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, Tokyo, Japan.
  • Shuto Y; Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, Tokyo, Japan.
  • Takano Y; Department of Radiological Technology, National Cancer Center Hospital, Tokyo, Japan.
  • Kobayashi Y; Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, Tokyo, Japan.
  • Kishida H; Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, Tokyo, Japan.
  • Urago Y; Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, Tokyo, Japan.
  • Nishitani M; Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, Tokyo, Japan.
  • Nishina S; Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, Tokyo, Japan.
  • Arai K; Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, Tokyo, Japan.
  • Igaki H; Department of Radiological Technology, National Cancer Center Hospital, Tokyo, Japan.
Imaging Sci Dent ; 54(2): 129-137, 2024 Jun.
Article in En | MEDLINE | ID: mdl-38948189
ABSTRACT

Purpose:

Patients with head and neck cancer (HNC) who undergo dental procedures during radiotherapy (RT) face an increased risk of developing osteoradionecrosis (ORN). Accordingly, new tools must be developed to extract critical information regarding the dose delivered to the teeth and mandible. This article proposes a novel approach for visualizing 3-dimensional planned dose distributions on panoramic reconstruction computed tomography (pCT) images. Materials and

Methods:

Four patients with HNC who underwent volumetric modulated arc therapy were included. One patient experienced ORN and required the extraction of teeth after RT. In the study approach, the dental arch curve (DAC) was defined using an open-source platform. Subsequently, pCT images and dose distributions were generated based on the new coordinate system. All teeth and mandibles were delineated on both the original CT and pCT images. To evaluate the consistency of dose metrics, the Mann-Whitney U test and Student t-test were employed.

Results:

A total of 61 teeth and 4 mandibles were evaluated. The correlation coefficient between the 2 methods was 0.999, and no statistically significant difference was observed (P>0.05). This method facilitated a straightforward and intuitive understanding of the delivered dose. In 1 patient, ORN corresponded to the region of the root and the gum receiving a high dosage (approximately 70 Gy).

Conclusion:

The proposed method particularly benefits dentists involved in the management of patients with HNC. It enables the visualization of a 3-dimensional dose distribution in the teeth and mandible on pCT, enhancing the understanding of the dose delivered during RT.