A Novel Apparatus for the Fully Automated Extraction and Online Liquid Chromatographic Analysis of Solid Environmental Samples: Application to the Pressurized Hot Water Extraction of Pharmaceuticals in Soil.
Bonaccorso, Giulia; Renai, Lapo; Checchini, Leonardo; Del Bubba, Massimo.
Affiliation
  • Bonaccorso G; Department of Chemistry "Ugo Schiff", University of Florence, Via della Lastruccia 3, 50019 Sesto Fiorentino, Florence, Italy.
  • Renai L; Department of Chemistry "Ugo Schiff", University of Florence, Via della Lastruccia 3, 50019 Sesto Fiorentino, Florence, Italy.
  • Checchini L; Department of Chemistry "Ugo Schiff", University of Florence, Via della Lastruccia 3, 50019 Sesto Fiorentino, Florence, Italy.
  • Del Bubba M; Department of Chemistry "Ugo Schiff", University of Florence, Via della Lastruccia 3, 50019 Sesto Fiorentino, Florence, Italy.
Anal Chem ; 96(28): 11390-11396, 2024 07 16.
Article in En | MEDLINE | ID: mdl-38965040
ABSTRACT
A new self-assembled apparatus for the extraction of solid samples was designed and implemented to perform a recirculated pressurized hot water extraction (R-PHWE) directly coupled to liquid chromatography-tandem mass spectrometry. To investigate the potential of this new extraction apparatus, 34 target pharmaceutical compounds were analyzed in loam, silt-loam, and silty-clay-loam soils. The target analytes were characterized by heterogeneous physicochemical properties (e.g., -1.60 ≤ log D ≤ 5.91 at pH = 7.2, i.e., at the mean pH values of the three soils). Design of experiments (DoE) was used to identify the best extraction conditions for the target analytes by studying temperature, pressure, and number of extraction cycles. The results of DoE optimization pointed out the significant influence of the number of cycles on recovery. The application of DoE set point to the three reference soils provided recoveries ≥60% for 21-25 out the 34 target analytes, depending on soil. Good recovery precision (<25%) and moderate suppressive matrix effect (≤40%) were found for most target analytes, regardless of the soil considered. The optimized R-PHWE procedure evidenced statistically higher recoveries for 16 out of 34 target analytes when compared to conventional off-line dynamic PHWE.