Your browser doesn't support javascript.
loading
Determination of rotation center and diameter of femoral heads using off-the-shelf augmented reality hardware for navigation.
Van Ravestyn, Antoine; Frantz, Taylor; Vandemeulebroucke, Jef; Jansen, Bart; Duerinck, Johnny; Scheerlinck, Thierry.
Affiliation
  • Van Ravestyn A; Department of Orthopedic Surgery and Traumatology, Universitair Ziekenhuis Brussel (UZ Brussel), Laarbeeklaan 101, 1090, Brussels, Belgium. antoine.van.ravestyn@vub.be.
  • Frantz T; Vrije Universiteit Brussel (VUB), Research Group BEFY-ORTHO, Laarbeeklaan 103, 1090, Brussels, Belgium. antoine.van.ravestyn@vub.be.
  • Vandemeulebroucke J; Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), Pleinlaan 2, 1050, Brussels, Belgium.
  • Jansen B; IMEC, Kapeldreef 75, 3001, Leuven, Belgium.
  • Duerinck J; Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), Pleinlaan 2, 1050, Brussels, Belgium.
  • Scheerlinck T; IMEC, Kapeldreef 75, 3001, Leuven, Belgium.
Sci Rep ; 14(1): 15458, 2024 07 04.
Article in En | MEDLINE | ID: mdl-38965266
ABSTRACT
In total hip arthroplasty (THA), determining the center of rotation (COR) and diameter of the hip joint (acetabulum and femoral head) is essential to restore patient biomechanics. This study investigates on-the-fly determination of hip COR and size, using off-the-shelf augmented reality (AR) hardware. An AR head-mounted device (HMD) was configured with inside-out infrared tracking enabling the determination of surface coordinates using a handheld stylus. Two investigators examined 10 prosthetic femoral heads and cups, and 10 human femurs. The HMD calculated the diameter and COR through sphere fitting. Results were compared to data obtained from either verified prosthetic geometry or post-hoc CT analysis. Repeated single-observer measurements showed a mean diameter error of 0.63 mm ± 0.48 mm for the prosthetic heads and 0.54 mm ± 0.39 mm for the cups. Inter-observer comparison yielded mean diameter errors of 0.28 mm ± 0.71 mm and 1.82 mm ± 1.42 mm for the heads and cups, respectively. Cadaver testing found a mean COR error of 3.09 mm ± 1.18 mm and a diameter error of 1.10 mm ± 0.90 mm. Intra- and inter-observer reliability averaged below 2 mm. AR-based surface mapping using HMD proved accurate and reliable in determining the diameter of THA components with promise in identifying COR and diameter of osteoarthritic femoral heads.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Arthroplasty, Replacement, Hip / Femur Head / Augmented Reality / Hip Prosthesis Limits: Female / Humans / Male Language: En Journal: Sci Rep Year: 2024 Document type: Article Affiliation country: Bélgica

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Arthroplasty, Replacement, Hip / Femur Head / Augmented Reality / Hip Prosthesis Limits: Female / Humans / Male Language: En Journal: Sci Rep Year: 2024 Document type: Article Affiliation country: Bélgica