Comparison of UV/PS and VUV/PS as ultrafiltration pretreatment: Performance, mechanisms, DBPs formation and toxicity assessment.
Chen, Shengnan; Zhao, Zhiwei; Li, Li; Cui, Fuyi.
Affiliation
  • Chen S; College of Environment and Ecology, Chongqing University, Chongqing 400045, PR China.
  • Zhao Z; College of Environment and Ecology, Chongqing University, Chongqing 400045, PR China; School of Civil and Transportation Engineering, Guangdong University of Technology, Guangzhou 510006, PR China. Electronic address: hit_zzw@163.com.
  • Li L; College of Environment and Ecology, Chongqing University, Chongqing 400045, PR China.
  • Cui F; College of Environment and Ecology, Chongqing University, Chongqing 400045, PR China.
Sci Total Environ ; 946: 174457, 2024 Oct 10.
Article in En | MEDLINE | ID: mdl-38969137
ABSTRACT
Ultrafiltration (UF) is widely used in drinking water plants, nevertheless, it still encounters challenges stemming from inevitable membrane fouling caused by natural organic matter (NOM). Herein, this work applied VUV/PS as UF membrane pretreatment and used UV/PS for comparison. VUV/PS system exhibited superior ability in removing NOM compared to UV/PS system. HO and SO4- played crucial roles in the degradation. [SO4-]ss was notably higher than [HO]ss in the systems, yet HO was of greater significance. [HO]ss and [SO4-]ss in the VUV/PS process were remarkably higher than those in the UV/PS process, due to the function of 185 nm photons. VUV/PS pretreatment basically recovered flux and effectively reduced fouling resistance, with better performance than UV/PS. Fouling mechanism was dominated by multiple mechanisms after UV/PS pretreatment, whereas it was transformed into pore blockage after VUV/PS pretreatment. Moreover, the UF effluent quality after VUV/PS pretreatment outperformed that of UV/PS but fell short of that without pretreatment, possibly due to the generation of abundant low MW substances under the action of HO and SO4-. After chlorine disinfection, UV/PS and VUV/PS pretreatments increased the DBPs production and cytotoxicity. Specifically, oxidant PS affected the membrane surface morphology and fouling behaviors, and had no obvious effect on interception performance and mechanical properties. In actual water treatment, VUV/PS and UV/PS pretreatments exhibited excellent performance in alleviating membrane fouling, improving water quality, and reducing DBPs formation and acute toxicity.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Sci Total Environ Year: 2024 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Sci Total Environ Year: 2024 Document type: Article