Your browser doesn't support javascript.
loading
Dynamic swatch testing of liquid aerosols in a laboratory-sized recirculating wind tunnel.
Yu, Seung Jung; Kim, Goonhyeok; Jung, Hyunsook; Jung, Heesoo; Jung, Jaewuk; Kim, Daegyoum.
Affiliation
  • Yu SJ; Chem-Bio Technology Center, Agency for Defense Development, Yuseong-Gu, Daejeon, 34063, Republic of Korea.
  • Kim G; Chem-Bio Technology Center, Agency for Defense Development, Yuseong-Gu, Daejeon, 34063, Republic of Korea.
  • Jung H; Chem-Bio Technology Center, Agency for Defense Development, Yuseong-Gu, Daejeon, 34063, Republic of Korea. junghs@add.re.kr.
  • Jung H; Weapon Systems Engineering, University of Science and Technology, Gajeong-Ro, Yuseung-Gu, Deajeon, 34113, Republic of Korea. junghs@add.re.kr.
  • Jung J; Chem-Bio Technology Center, Agency for Defense Development, Yuseong-Gu, Daejeon, 34063, Republic of Korea. hsjung@add.re.kr.
  • Kim D; Department of Mechanical Engineering, KAIST, Daejeon, 34131, Republic of Korea.
Sci Rep ; 14(1): 16539, 2024 Jul 17.
Article in En | MEDLINE | ID: mdl-39020107
ABSTRACT
Chemical warfare agents (CWAs) pose a threat as gaseous substances and as liquid aerosols, necessitating chemical warfare-protective clothing for soldiers. The paramount consideration lies in the effectiveness of the clothing as a barrier against the pertinent CWAs. This paper presents a dynamic swatch test method aimed at evaluating the performance of such clothing against liquid-phase aerosol penetration. Central to the methodology is a specialized test cell designed to rotate to the left and right, integrated within a laboratory wind tunnel, replicating mission-relevant conditions with varying wind speeds. Utilizing di(2-ethylhexyl) sebacate particles as liquid aerosols, tests were conducted at wind speeds of 1.0, 3.0, and 5.0 m/s. Penetration assessment relied on analyzing particle counts downstream and upstream of the fabric, with preliminary studies showing that higher wind speeds and fabric air permeabilities increase penetration at an equivalent face velocity of 5.0 cm/s. Interestingly, penetration decreased when fabric samples were subjected to rotation. The system and methodology devised demonstrated consistent and repeatable results, offering valuable insights into optimizing the effectiveness of chemical warfare-protective clothing. This research contributes to advancing methodologies for testing protective clothing, crucial for ensuring the safety of military personnel in hazardous environments.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Sci Rep Year: 2024 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Sci Rep Year: 2024 Document type: Article