Your browser doesn't support javascript.
loading
Three-dimensional analysis of bone site grafting on the upper extremity on computed tomography scans.
Villarreal-Villarreal, Gregorio Alejandro; Simental-Mendía, Mario; Arturo Ramírez Mendoza, Diego; Peña-Martínez, Víctor Manuel; Negreros-Osuna, Adrian A; Alberto Acosta-Olivo, Carlos.
Affiliation
  • Villarreal-Villarreal GA; Facultad de Medicina y Hospital Universitario Dr José Eleuterio González, Universidad Autonoma de Nuevo Leon Monterrey, México.
  • Simental-Mendía M; Facultad de Medicina y Hospital Universitario Dr José Eleuterio González, Universidad Autonoma de Nuevo Leon Monterrey, México.
  • Arturo Ramírez Mendoza D; Facultad de Medicina y Hospital Universitario Dr José Eleuterio González, Universidad Autonoma de Nuevo Leon Monterrey, México.
  • Peña-Martínez VM; Facultad de Medicina y Hospital Universitario Dr José Eleuterio González, Universidad Autonoma de Nuevo Leon Monterrey, México.
  • Negreros-Osuna AA; Facultad de Medicina y Hospital Universitario Dr José Eleuterio González, Universidad Autonoma de Nuevo Leon Monterrey, México.
  • Alberto Acosta-Olivo C; Facultad de Medicina y Hospital Universitario Dr José Eleuterio González, Universidad Autonoma de Nuevo Leon Monterrey, México.
J Orthop Surg (Hong Kong) ; 32(2): 10225536241268607, 2024.
Article in En | MEDLINE | ID: mdl-39054928
ABSTRACT

PURPOSE:

To perform a quantitative analysis of the amount of cancellous bone in the distal radius and olecranon process by segmentation of computed tomographic scans. As a secondary analysis, the bone density by Hounsfield units was evaluated at the same sites.

METHODS:

Computed tomography angiography images of the upper extremity were analyzed using 3-D Slicer™ medical imaging software. Bone volume (cm3) and density (Hounsfield units) from the cancellous bone between the distal radius and the olecranon process were compared by creating an advanced three-dimensional model. The images were analyzed in duplicate, and an intraclass correlation was performed to assess measurement consistency.

RESULTS:

Twenty subjects were included. A total volume of 5.01 ± 1.21 cm3 and 5.81 ± 1.61 cm3 for the distal radius and the olecranon process (p < .0001), respectively, was found. Regarding Hounsfield units, the density of the olecranon process was 303.1 ± 73.26, and the distal radius was 206.5 ± 63.73 (p < .0001). All intraclass correlation coefficients were >0.992.

CONCLUSION:

These results suggest that the olecranon process has a greater volume and a higher bone mineral density than the distal radius. With these results, the surgeon will have the ability to decide the quantity and quality of bone grafts according to the surgical procedure.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Radius / Tomography, X-Ray Computed / Bone Density / Imaging, Three-Dimensional Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: J Orthop Surg (Hong Kong) / J. orthop. surg. (Hong Kong) / Journal of orthopaedic surgery (Hong Kong. Online) Journal subject: ORTOPEDIA Year: 2024 Document type: Article Country of publication: Reino Unido

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Radius / Tomography, X-Ray Computed / Bone Density / Imaging, Three-Dimensional Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: J Orthop Surg (Hong Kong) / J. orthop. surg. (Hong Kong) / Journal of orthopaedic surgery (Hong Kong. Online) Journal subject: ORTOPEDIA Year: 2024 Document type: Article Country of publication: Reino Unido