Your browser doesn't support javascript.
loading
A homogeneous binary matrix assisted laser desorption/ionization time-of-flight mass spectrometry assay for determination of artificial sweeteners in beverages.
Wang, Mengzhen; Ling, Ling; Wang, Shuyi; Ding, Chuan-Fan.
Affiliation
  • Wang M; Key Laboratory of Advanced Mass Spectrometry and Molecular Analysis of Zhejiang Province, Institute of Mass Spectrometry, School of Material Science and Chemical Engineering, Ningbo University, Ningbo, Zhejiang 315211, China.
  • Ling L; Key Laboratory of Advanced Mass Spectrometry and Molecular Analysis of Zhejiang Province, Institute of Mass Spectrometry, School of Material Science and Chemical Engineering, Ningbo University, Ningbo, Zhejiang 315211, China. Electronic address: lingling@nbu.edu.cn.
  • Wang S; Key Laboratory of Advanced Mass Spectrometry and Molecular Analysis of Zhejiang Province, Institute of Mass Spectrometry, School of Material Science and Chemical Engineering, Ningbo University, Ningbo, Zhejiang 315211, China.
  • Ding CF; Key Laboratory of Advanced Mass Spectrometry and Molecular Analysis of Zhejiang Province, Institute of Mass Spectrometry, School of Material Science and Chemical Engineering, Ningbo University, Ningbo, Zhejiang 315211, China. Electronic address: dingchuanfan@nbu.edu.cn.
Food Chem ; 460(Pt 2): 140597, 2024 Jul 25.
Article in En | MEDLINE | ID: mdl-39079360
ABSTRACT
Artificial sweeteners have been widely used as additives in various beverages. Due to the safety risks associated with artificial sweeteners, it is essential to develop a simple, rapid, and high-throughput method for the analysis of artificial sweeteners. Here, we report a homogeneous binary matrix assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) assay for the simultaneous analysis of sweeteners including aspartame (ASP), neotame (NEO), and advantame (ADV) with a simple dilution step. The combination of nanodiamonds with 2,5-dihydroxybenzoic acid effectively improved the signal response of sweeteners, decreased the background noise, and improved the "spot-to-spot" repeatability. After the optimization, the method exhibits low limits of detection (ASP 20 nΜ; NEO 10 nΜ; ADV 5 nΜ), good linearity (r > 0.995), satisfactory accuracy (96.2-103.0%), and lower RSDs (1.5-5.8%). Finally, the target sweeteners in 17 soft beverages were successfully determined with this method, showing the potential for the routine analysis of artificial sweeteners.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Food Chem Year: 2024 Document type: Article Affiliation country: China

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Food Chem Year: 2024 Document type: Article Affiliation country: China