Monitoring residual solvents in pharmaceutical products using a portable pre-concentration GC-PID.
Adetunji, Olajide; Kaur, Sargun; Wheeler, Nicole; Nam, Victor; Shi, Honglan; Nam, Paul.
Affiliation
  • Adetunji O; Department of Chemistry, Center for Biomedical Research, Missouri University of Science and Technology, Rolla, MO 65409, USA.
  • Kaur S; Department of Chemistry, Center for Biomedical Research, Missouri University of Science and Technology, Rolla, MO 65409, USA.
  • Wheeler N; Department of Chemistry, Center for Biomedical Research, Missouri University of Science and Technology, Rolla, MO 65409, USA.
  • Nam V; Department of Chemistry, Center for Biomedical Research, Missouri University of Science and Technology, Rolla, MO 65409, USA.
  • Shi H; Department of Chemistry, Center for Biomedical Research, Missouri University of Science and Technology, Rolla, MO 65409, USA.
  • Nam P; Department of Chemistry, Center for Biomedical Research, Missouri University of Science and Technology, Rolla, MO 65409, USA. Electronic address: nam@mst.edu.
J Pharm Biomed Anal ; 249: 116327, 2024 Oct 15.
Article in En | MEDLINE | ID: mdl-39089199
ABSTRACT
Pharmaceutical manufacturing utilizes solvents at different stages of production. Some of the harmful solvent residuals may be retained in the final product; therefore, they need to be monitored for quality control and to meet the regulation requirement. Here, a novel method capable of rapidly analyzing residual solvents in pharmaceutical products was developed using a compact-portable gas chromatography with a photoionization detector (GC-PID). The method consists of modified Tedlar® bag sampling, online pre-concentration, separation of volatiles by miniaturized GC, and micro-PID detection. The method detection limits of selected residual solvents were in the range of 26.00 - 52.03 pg/mL which is much lower than the pharmaceutical compliance concentration limits. Limits of detection > 520 pg of analyte per grams of sample was also determined for the over-the-counter drugs. The method performance showed rapid speed (5 min), linear calibration (r2 < 0.99), and repeatable retention time (RSD < 0.4 %). Direct analysis of residual solvents in solid samples was conducted without the need for complex sample preparation. The method validation using over-the-counter pharmaceutical products yielded excellent accuracy (recovery > 91.2 %) and precision (RSD < 6.5 %) for the selected residual solvents, including 1,4-dioxane, benzene, chlorobenzene, cyclohexane, xylenes, and toluene. This portable and rapid method could be deployed during the pharmaceutical drug manufacturing processes for quality control.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Solvents / Limit of Detection Language: En Journal: J Pharm Biomed Anal Year: 2024 Document type: Article Country of publication: Reino Unido