Your browser doesn't support javascript.
loading
Phase-resolved MRI for measurement of pulmonary perfusion and ventilation defects in comparison with dynamic contrast-enhanced MRI and 129Xe MRI.
Ouyang, Tao; Tang, Yichen; Zhang, Chen; Yang, Qi.
Affiliation
  • Ouyang T; Department of Radiology, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China.
  • Tang Y; Key Laboratory of Medical Engineering for Cardiovascular Disease, Ministry of Education, Beijing, China.
  • Zhang C; Laboratory for Clinical Medicine, Capital Medical University, Beijing, China.
  • Yang Q; Department of Radiology, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China.
BMJ Open Respir Res ; 11(1)2024 Aug 07.
Article in En | MEDLINE | ID: mdl-39117397
ABSTRACT

INTRODUCTION:

This meta-analysis aims to evaluate the agreement and correlation between phase-resolved functional lung MRI (PREFUL MRI) and dynamic contrast-enhanced (DCE) MRI in evaluating perfusion defect percentage (QDP), as well as the agreement between PREFUL MRI and 129Xe MRI in assessing ventilation defect percentage (VDP).

METHOD:

A systematic search was conducted in the Medline, Embase and Cochrane Library databases to identify relevant studies comparing QDP and VDP measured by DCE MRI and 129Xe MRI compared with PREFUL MRI. Meta-analytical techniques were applied to calculate the pooled weighted bias, limits of agreement (LOA) and correlation coefficient. The publication bias was assessed using Egger's regression test, while heterogeneity was assessed using Cochran's Q test and Higgins I2 statistic.

RESULTS:

A total of 399 subjects from 10 studies were enrolled. The mean difference and LOA were -2.31% (-8.01% to 3.40%) for QDP and 0.34% (-4.94% to 5.62%) for VDP. The pooled correlations (95% CI) were 0.65 (0.55 to 0.73) for QDP and 0.72 (0.61 to 0.80) for VDP. Furthermore, both QDP and VDP showed a negative correlation with forced expiratory volume in 1 s (FEV1). The pooled correlation between QDP and FEV1 was -0.51 (-0.74 to -0.18), as well as between VDP and FEV1 was -0.60 (-0.73 to -0.44).

CONCLUSIONS:

PREFUL MRI is a promising imaging for the assessment of lung function, as it demonstrates satisfactory deviations and LOA when compared with DEC MRI and 129Xe MRI. PROSPERO REGISTRATION NUMBER CRD42023430847.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Magnetic Resonance Imaging / Contrast Media / Lung Limits: Humans Language: En Journal: BMJ Open Respir Res / BMJ open respiratory research Year: 2024 Document type: Article Affiliation country: China Country of publication: Reino Unido

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Magnetic Resonance Imaging / Contrast Media / Lung Limits: Humans Language: En Journal: BMJ Open Respir Res / BMJ open respiratory research Year: 2024 Document type: Article Affiliation country: China Country of publication: Reino Unido