Your browser doesn't support javascript.
loading
Comparison of Different Intraoral Scanners With Prefabricated Aid on Accuracy and Framework Passive Fit of Digital Complete-Arch Implant Impression: An In Vitro Study.
Fu, Xiao-Jiao; Liu, Min; Shi, Jun-Yu; Deng, Ke; Lai, Hong-Chang; Gu, Wen; Zhang, Xiao-Meng.
Affiliation
  • Fu XJ; Department of Oral and Maxillofacial Implantology, Shanghai PerioImplant Innovation Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, National Clinical Research Center fo
  • Liu M; Department of Oral and Maxillofacial Implantology, Shanghai PerioImplant Innovation Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, National Clinical Research Center fo
  • Shi JY; Department of Oral and Maxillofacial Implantology, Shanghai PerioImplant Innovation Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, National Clinical Research Center fo
  • Deng K; Division of Periodontology and Implant Dentistry, The Faulty of Dentistry, The University of Hong Kong, Hong Kong, China.
  • Lai HC; Department of Oral and Maxillofacial Implantology, Shanghai PerioImplant Innovation Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, National Clinical Research Center fo
  • Gu W; Department of Oral and Maxillofacial Implantology, Shanghai PerioImplant Innovation Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, National Clinical Research Center fo
  • Zhang XM; Department of Oral and Maxillofacial Implantology, Shanghai PerioImplant Innovation Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, National Clinical Research Center fo
Article in En | MEDLINE | ID: mdl-39233386
ABSTRACT

OBJECTIVES:

This study aimed to compare the accuracy of digital complete-arch implant impressions with prefabricated aids using three intraoral scanners (IOSs) and explore the correlation between virtual deviation measurement and physical framework misfit. MATERIALS AND

METHODS:

Four edentulous maxillary master models with four and six parallel and angular implants were fabricated and scanned by a laboratory scanner as reference scans. Ten scans of each master model were acquired using three IOSs (IOS-T, IOS-M, and IOS-A) with and without prefabricated aids. Trueness and precision of root mean square (RMS) errors were measured. Ten aluminum alloy frameworks were fabricated, and the misfit was measured with a micro-computed tomography scan with one screw tightened.

RESULTS:

Trueness and precision showed significant improvement when prefabricated aids were used for all three IOSs (p < 0.010). Median (interquartile range) RMS errors of trueness reduced from 67.5 (30.4) to 61.8 (30.3) µm, from 100.6 (35.4) to 45.9 (15.1) µm, and from 52.7 (33.2) to 41.1 (22.5) µm for scanner IOS-T, IOS-M, and IOS-A, respectively (p < 0.010). The precision of IOS-A and IOS-M was significantly better than IOS-T when using prefabricated aid (p < 0.001). RMS errors and the maximum marginal misfit of the framework were significantly correlated (p < 0.001, R2 = 0.845).

CONCLUSIONS:

With the prefabricated aids, the accuracy of IOSs enhanced significantly in digital complete-arch implant impressions. Three IOSs showed different levels of improvement in accuracy. Virtual RMS errors <62.2 µm could be the clinically acceptable threshold (150 µm) for framework passive fit.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Clin Oral Implants Res / Clin. oral implants res / Clinical oral implants research Journal subject: ODONTOLOGIA Year: 2024 Document type: Article Country of publication: Dinamarca

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Clin Oral Implants Res / Clin. oral implants res / Clinical oral implants research Journal subject: ODONTOLOGIA Year: 2024 Document type: Article Country of publication: Dinamarca