Two-stage screening for obstructive sleep apnea in the primary practice setting.
Pangerc, Andrej; Petek Ster, Marija; Dolenc Groselj, Leja.
Affiliation
  • Pangerc A; Department of Family Medicine, Faculty of Medicine, University of Ljubljana, 1000, Ljubljana, Slovenia. andrej.pangerc@gmail.com.
  • Petek Ster M; Department of Family Medicine, Faculty of Medicine, University of Ljubljana, 1000, Ljubljana, Slovenia.
  • Dolenc Groselj L; Institute of Clinical Neurophysiology, Division of Neurology, University Medical Centre Ljubljana, 1000, Ljubljana, Slovenia.
Sleep Breath ; 2024 Sep 10.
Article in En | MEDLINE | ID: mdl-39256328
ABSTRACT

PURPOSE:

To evaluate the effectiveness of a two-stage screening model for obstructive sleep apnea (OSA) in primary care that combines the STOP-BANG questionnaire (SBQ) with an automated home sleep apnea test (HSAT).

METHODS:

This cross-sectional study was conducted from August 2018 to August 2022 in four Slovenian primary care practices. It included 153 randomly selected patients aged 18 to 70 years who visited the practice for any reason. Participants completed the SBQ and underwent HSAT with type III polygraphy on the same night. The HSAT recordings were scored automatically and by an experienced, accredited somnologist.

RESULTS:

There was a strong correlation between manual and automated HSAT scorings for the detection of OSA (Pearson's r = 0.93). Cohen's kappa was 0.80 for OSA (respiratory event index (REI) ≥ 5) and 0.77 for OSA severity categorization. The two-stage model demonstrated sensitivity of 64%, a specificity of 97.4%, a positive predictive value (PPV) of 96.0%, a negative predictive value (NPV) of 73.8% and an accuracy of 81.1% for any OSA (REI ≥ 5). For moderate to severe OSA (REI ≥ 15), the model showed 72.7% sensitivity, 96.7% specificity, 85.7% PPV, 92.8% NPV and 91.5% accuracy.

CONCLUSIONS:

The two-stage model for OSA screening combining the SBQ and automated HSAT was shown to be effective in primary care, especially for moderate and severe OSA. This method provides a practical and efficient approach for the early detection of OSA.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Sleep Breath Journal subject: NEUROLOGIA / OTORRINOLARINGOLOGIA Year: 2024 Document type: Article Affiliation country: Eslovenia Country of publication: Alemania

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Sleep Breath Journal subject: NEUROLOGIA / OTORRINOLARINGOLOGIA Year: 2024 Document type: Article Affiliation country: Eslovenia Country of publication: Alemania