Your browser doesn't support javascript.
loading
A Reliable and Straightforward Combination of vortex-assisted Dispersive Magnetic solid-phase Extraction with Direct Sorbent Sampling for Highly Sensitive Silver Determination in Water Samples Using Flame and Metal Furnace AAS.
Santos, Diego Prudencio Dos; Ferreira, Milena do Prado; Diniz, Kristiany Moreira; Segatelli, Mariana Gava; Figueiredo, Eduardo Costa de; Tarley, César Ricardo Teixeira.
Affiliation
  • Santos DPD; Department of Chemistry, State University of Londrina, Rodovia Celso Garcia Cid, PR 445, Km 380, Londrina, PR, 86050-482, Brazil.
  • Ferreira MDP; Department of Chemistry, State University of Londrina, Rodovia Celso Garcia Cid, PR 445, Km 380, Londrina, PR, 86050-482, Brazil.
  • Diniz KM; Federal Institute of Parana (IFPR), Campus Irati, Irati, PR, 84507-302, Brazil.
  • Segatelli MG; Department of Chemistry, State University of Londrina, Rodovia Celso Garcia Cid, PR 445, Km 380, Londrina, PR, 86050-482, Brazil.
  • Figueiredo EC; Laboratory of Toxicant and Drug Analyses, Faculty of Pharmaceutical Sciences, Federal University of Alfenas, Alfenas, MG, 37130-001, Brazil.
  • Tarley CRT; Department of Chemistry, State University of Londrina, Rodovia Celso Garcia Cid, PR 445, Km 380, Londrina, PR, 86050-482, Brazil. ctarleyquim@yahoo.com.br.
Bull Environ Contam Toxicol ; 113(4): 42, 2024 Sep 21.
Article in En | MEDLINE | ID: mdl-39306638
ABSTRACT
In the present paper, the assessment of vortex-assisted dispersive magnetic solid-phase extraction using amino-functionalized mesoporous combined with direct magnetic sorbent sampling (DMSS) in flame or furnace atomic absorption spectrometry (FAAS or FF-AAS) was demonstrated for highly sensitive silver determination in water samples. The developed method showed significant enrichment factors compared to conventional pneumatic nebulization by FAAS, 607 for DMSS-FF-AAS and 114 for DMSS-FAAS. The analytical curve showed linearity in the range from 5.0 to 70.0 µg L- 1 and 1.0 to 15.0 µg L- 1 and limits of detection of 0.59 and 0.09 µg L- 1 for DMSS-FAAS and DMSS-FF-AAS, respectively. The intra and inter-day precision evaluated as a percentage of the relative standard deviation (RSD,%) ranged from 1.89 to 4.71% for levels of 25.0 and 65.0 µg L- 1. The method was applied in different kinds of water samples without matrix effects, yielding recovery values from 90 to 110%.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Silver / Spectrophotometry, Atomic / Water Pollutants, Chemical / Solid Phase Extraction Language: En Journal: Bull Environ Contam Toxicol Year: 2024 Document type: Article Affiliation country: Brasil Country of publication: Estados Unidos

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Silver / Spectrophotometry, Atomic / Water Pollutants, Chemical / Solid Phase Extraction Language: En Journal: Bull Environ Contam Toxicol Year: 2024 Document type: Article Affiliation country: Brasil Country of publication: Estados Unidos