Your browser doesn't support javascript.
loading
Limiar de positividade e sensibilidade dos métodos de Faust et al. e Lutz para detecção de cistos de Giardia duodenalis / Positivity threshold and sensitivity of methods of Faust et al. and Lutz for detection of Giardia duodenalis cysts
Cognialli, Regielly Caroline Raimundo; Haidamak, Juciliane; Vayego, Stela Adami; Klisiowicz, Débora do Rocio.
Affiliation
  • Cognialli, Regielly Caroline Raimundo; Universidade Federal do Paraná. Curitiba. BR
  • Haidamak, Juciliane; Universidade Federal do Paraná. Curitiba. BR
  • Vayego, Stela Adami; Universidade Federal do Paraná. Curitiba. BR
  • Klisiowicz, Débora do Rocio; Universidade Federal do Paraná. Curitiba. BR
Rev. bras. anal. clin ; 49(1): 100-104, jun.16, 2017. tab
Article in Portuguese | LILACS | ID: biblio-1151852
Responsible library: BR408.1
Localization: BR408.1
RESUMO
Objetivo: O presente estudo teve como objetivo determinar e comparar o limiar de positividade e a sensibilidade dos métodos de centrífugo-flutuação em sulfato de zinco (Faust et al.) e sedimentação espontânea (Lutz) para o diagnóstico de cistos de Giardia duodenalis. Métodos: Para obtenção de amostras fecais com quantidades conhecidas de cistos de G. duodenalis, amostras positivas para o parasito foram purificadas e quantificadas, e posteriormente alíquotas com diferentes quantidades foram adicionadas a amostras fecais negativas para parasitos. Após a contaminação de oito amostras negativas com quantidades variando entre 1.000 e 200.000 cistos por grama de fezes (c/g/f), as mesmas foram submetidas aos métodos de Faust et al. e Lutz, onde o primeiro se mostrou mais sensível para a detecção de cistos de G. duodenalis. Resultados: O limiar de positividade do método de Faust et al. foi de 11.000 c/g/f, e do método de Lutz foi de 100.000 c/g/f, portanto, cargas parasitárias inferiores a esses limiares levariam a resultados falso-negativos. Conclusão: O método de Lutz não é adequado para o diagnóstico de giardíase, portanto deve ser sempre utilizado em conjunto com o método de Faust et al.
ABSTRACT
Objective: The present study aimed to determine and compare the positivity threshold and sensitivity of the methods of zinc sulfate centrifugal flotation (Faust et al.) and spontaneous sedimentation (Lutz) for the diagnosis of Giardia duodenalis. Methods: To obtain fecal samples containing known amounts of G. duodenalis cysts, the samples with the parasite were purified and quantified, then aliquots with different amounts were added to fecal samples negative for parasites. After the contamination of eight negative samples with amounts ranging between 1.000 and 200.000 cysts per gram of feces, they were subjected to methods of Faust et al. and Lutz, where the first was more sensitive for the detection of G. duodenalis cysts. Results: The positivity threshold of the method of Faust et al. was 11.000 c/g/f, and the method of Lutz was 100.000 c/g/f, so parasitic loads below those thresholds would lead to false-negative results. Conclusion: The method of Lutz is not suitable for the diagnosis of giardiasis, therefore must always be associated with the method Faust et al.
Subject(s)


Full text: Available Collection: International databases Database: LILACS Main subject: Parasitic Diseases / Sensitivity and Specificity / Giardia lamblia / Analytic Sample Preparation Methods Type of study: Diagnostic study Limits: Humans Language: Portuguese Journal: Rev. bras. anal. clin Journal subject: Pathology Year: 2017 Document type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal do Paraná/BR

Full text: Available Collection: International databases Database: LILACS Main subject: Parasitic Diseases / Sensitivity and Specificity / Giardia lamblia / Analytic Sample Preparation Methods Type of study: Diagnostic study Limits: Humans Language: Portuguese Journal: Rev. bras. anal. clin Journal subject: Pathology Year: 2017 Document type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal do Paraná/BR
...