Your browser doesn't support javascript.
loading
Impact pf machines on plan quality: volumetric modulated arc therapy and intensity modulated radiation therapy
Clemente, S; Cozzolino, M; Oliviero, C; Fiorentino, A; Chiumento, C; Fusco, V.
Affiliation
  • Clemente, S; Istituto di Ricovero e Cura a Carattere Scientifico Centro Regionale Oncologico Basilicata(IRCCS CROB). Department of Radiation Oncology. Rionero in Vulture. Italy
  • Cozzolino, M; Istituto di Ricovero e Cura a Carattere Scientifico Centro Regionale Oncologico Basilicata(IRCCS CROB). Department of Radiation Oncology. Rionero in Vulture. Italy
  • Oliviero, C; Istituto di Ricovero e Cura a Carattere Scientifico Centro Regionale Oncologico Basilicata(IRCCS CROB). Department of Radiation Oncology. Rionero in Vulture. Italy
  • Fiorentino, A; Istituto di Ricovero e Cura a Carattere Scientifico Centro Regionale Oncologico Basilicata(IRCCS CROB). Department of Radiation Oncology. Rionero in Vulture. Italy
  • Chiumento, C; Istituto di Ricovero e Cura a Carattere Scientifico Centro Regionale Oncologico Basilicata(IRCCS CROB). Department of Radiation Oncology. Rionero in Vulture. Italy
  • Fusco, V; Istituto di Ricovero e Cura a Carattere Scientifico Centro Regionale Oncologico Basilicata(IRCCS CROB). Department of Radiation Oncology. Rionero in Vulture. Italy
Clin. transl. oncol. (Print) ; 16(2): 141-146, feb. 2014. tab, ilus
Article in En | IBECS | ID: ibc-127716
Responsible library: ES1.1
Localization: BNCS
ABSTRACT
PURPOSE: To evaluate the impact of different machines on plan quality using both intensity modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) techniques. MATERIALS AND METHODS: Eight patients with squamous cell carcinoma of the oropharynx were selected at random. Plans were computed for IMRT and VMAT Smart Arc, using Pinnacle TPS for an Elekta (IMRT-E, VMAT-E) and Varian linac (IMRT-V, VMAT-V). A three-dose level prescription was used to deliver 70, 63 and 58.1 Gy to regions of macroscopic, microscopic high- and low-risk disease, respectively. All doses were given in 35 fractions. Comparisons were performed on dose-volume histogram data, monitor units (MU), and delivery time. RESULTS: VMAT-E plans resulted slightly MU efficient (-24 % p < 0.05) compared to VMAT-V while IMRT-V shortened delivery time (-19 % p < 0.05) compared to IMRT-E. All the delivery techniques resulted in equivalent target coverage in terms of D(98) % and D(2) %. For VMAT technique, a significant improvement of 7 % in homogeneity index (HI) for PTV58.1 was observed for Varian machine. A slight improvement in OARs sparing was observed with Elekta machine both for IMRT and VMAT techniques. CONCLUSION: Similar plan quality was observed for Elekta and Varian linacs, significant differences were observed in delivery efficiency, as MU number and delivery times, in favor of Elekta and Varian, respectively (AU)
RESUMEN
No disponible
Subject(s)
Search on Google
Collection: 06-national / ES Database: IBECS Main subject: Particle Accelerators / Radiotherapy Planning, Computer-Assisted / Radiotherapy, Intensity-Modulated Type of study: Clinical_trials / Etiology_studies Limits: Humans Language: En Journal: Clin. transl. oncol. (Print) Year: 2014 Document type: Article
Search on Google
Collection: 06-national / ES Database: IBECS Main subject: Particle Accelerators / Radiotherapy Planning, Computer-Assisted / Radiotherapy, Intensity-Modulated Type of study: Clinical_trials / Etiology_studies Limits: Humans Language: En Journal: Clin. transl. oncol. (Print) Year: 2014 Document type: Article