Your browser doesn't support javascript.
loading
Nueva forma de entender las pruebas de condición física en relación con la salud / New Approach to Health-Related Physical Fitness Tests
Martínez-de-Haro, V; Peral-Rodríguez, P; Cid-Yagüe, L; Álvarez-Barrio, M. J.
Affiliation
  • Martínez-de-Haro, V; Universidad Autónoma de Madrid (UAM). Grupo de investigación “Actividad Física, Educación y Salud”. España
  • Peral-Rodríguez, P; CEIP Velázquez de Fuenlabrada. Grupo de investigación “Actividad Física, Educación y Salud” UAM. España
  • Cid-Yagüe, L; Universidad Autónoma de Madrid (UAM). Grupo de investigación “Actividad Física, Educación y Salud”. España
  • Álvarez-Barrio, M. J; Universidad Autónoma de Madrid (UAM). Grupo de investigación “Actividad Física, Educación y Salud”. España
Rev. int. med. cienc. act. fis. deporte ; 22(85): 129-151, mar.-mayo 2022. ilus, graf, tab
Article in En, Es | IBECS | ID: ibc-205432
Responsible library: ES1.1
Localization: ES15.1 - BNCS
RESUMEN
El objetivo de este trabajo es mostrar una nueva forma de entender la evaluación de la “condición física en relación con la salud”, para evitar la inactividad y el sedentarismo. Los antecedentes se encuentran en las baterías de test utilizadas desde 1976 hasta la actualidad. Se utiliza el concepto de salud de la OMS. Se analizan pruebas con criterios de funcionalidad, economía, validez, fiabilidad y especificidad. Se eligen las siguientes pruebas y se calculan los umbrales: 1425 s UKK Walk test (P75), 6 s en sprint test 20 m (P75), 19 repeticiones en Chair Stand Test (P25), 11 repeticiones Arm Curl Test (P25), -10,5 cm Back Scratch Test (P25), -17,5 cm en Chair Sit and Reach Test. Se propugna la elaboración de una batería de test universal e inclusiva y elaborar percentiles mundiales ayudados por el big data. (AU)
ABSTRACT
The aim of this research was to propose a new way of understanding health-related physical fitness assessment in order to prevent inactivity and sedentarism. The background lies in the test batteries used from 1976 to the present. WHO's health concept was used. Tests were analysed based on functionality, economy, validity, reliability and specificity criteria. The following tests were chosen and the thresholds were calculated: 1,425s in the UKK walk test (P75), 6s in the 20-m sprint test (P75), 19 repetitions in the chair stand test (P25), 11 repetitions in the arm curl test (P25), -10.5cm in the back scratch test (P25), -17.5cm in the chair sit-and-reach test (P25). It was proposed that a universal and inclusive test battery be developed and the percentiles for the world population are determined with the help of big data. (AU)
Subject(s)
Key words

Full text: 1 Collection: 06-national / ES Database: IBECS Main subject: Health / Noncommunicable Diseases / Motor Activity Limits: Humans Language: En / Es Journal: Rev. int. med. cienc. act. fis. deporte Year: 2022 Document type: Article

Full text: 1 Collection: 06-national / ES Database: IBECS Main subject: Health / Noncommunicable Diseases / Motor Activity Limits: Humans Language: En / Es Journal: Rev. int. med. cienc. act. fis. deporte Year: 2022 Document type: Article