Your browser doesn't support javascript.
loading
Diferencias en función de la gravedad de la atenuación pulmonar en varones con EPOC / Severity Related Differences in Lung Attenuation in Men With COPD
Torres, Isabel; Allona, María; Martínez, Marta; Lores, Vanesa; Rojo, blas; García-Río, Francisco.
Affiliation
  • Torres, Isabel; Hospital Universitario La Paz. Madrid. España
  • Allona, María; Hospital Universitario Madrid Norte Sanchinarro. Madrid. España
  • Martínez, Marta; Hospital Universitario La Paz. Madrid. España
  • Lores, Vanesa; Hospital Universitario La Paz. Madrid. España
  • Rojo, blas; Hospital Universitario La Paz. Madrid. España
  • García-Río, Francisco; Hospital Universitario La Paz. Madrid. España
Arch. bronconeumol. (Ed. impr.) ; 46(2): 56-63, feb. 2010. tab, ilus
Article in Es | IBECS | ID: ibc-76333
Responsible library: ES1.1
Localization: BNCS
RESUMEN
IntroducciónEl objetivo del estudio ha sido comparar la atenuación pulmonar inspiratoria y espiratoria en varones con enfermedad pulmonar obstructiva crónica (EPOC), según la gravedad, así como valorar la relación entre la atenuación del parénquima y la función pulmonar.Pacientes y métodosSe seleccionó a 55 varones con EPOC moderada-muy grave y clínicamente estables. Se les realizaron gasometría arterial, espirometría, pletismografía, difusión de monóxido de carbono y prueba de la marcha. La gravedad de la EPOC se clasificó en función de la escala GOLD y del índice BODE. Se realizó una tomografía computarizada de tórax de alta resolución en inspiración y espiración, utilizando un programa informático específico para medir la atenuación de las diferentes áreas pulmonares.ResultadosLa atenuación de los lóbulos inferiores fue menor en pacientes con EPOC grave y muy grave que en casos con enfermedad moderada, tanto en inspiración como en espiración. En los varones con EPOC moderada y grave se detectaron diferencias en la atenuación media de los lóbulos superiores. No se hallaron diferencias en función de los cuartiles del índice BODE. Los parámetros de obstrucción de la vía aérea se relacionaron principalmente con la atenuación de los lóbulos inferiores en espiración, mientras que los parámetros de hiperinsuflación se correlacionaron con la atenuación en inspiración. Por último, la capacidad de difusión se relacionó de forma independiente con el valor de atenuación espiratoria/inspiratoria de los lóbulos inferiores y la atenuación de los lóbulos inferiores en inspiración.ConclusionesSe observan diferencias en la atenuación pulmonar entre los diferentes grados de gravedad de la EPOC establecidos según la clasificación GOLD(AU)
ABSTRACT
Background and objetivesWe compare the inspiratory and expiratory regional lung densities between different levels of COPD severity (as assessed by the GOLD scale and by the BODE index), and to assess the relationship between regional lung densities and functional lung parameters.Patients and methodsFifty-five stable moderate-severe COPD men were selected. Functional evaluation included dyspnoea scale, blood gases, spirometry, plethysmography, diffusing capacity and six-minute walk test. Severity was classified according the GOLD scale and the BODE index. High resolution computed tomography (HRCT) scans of the entire lung at full inspiration and two sections at full expiration were obtained. Densitometry software was used to calculate the densities of the lung areas.ResultsInspiratory and expiratory mean lung densities (MLD) of the lower lobes were significantly lower in very severe and severe COPD patients than in moderate patients. In contrast, we only found differences between the upper lobe MLD values of moderate and severe COPD patients. Inspiratory and expiratory HRCT densities were similar among all BODE quartiles, for both the upper and lower lobes. In a multiple regression analysis, airway obstruction parameters were mainly related to the expiratory MLD of the lower lobes, whereas lung hyperinflation parameters were predicted by the inspiratory MLD of the lower lobes. Lastly, diffusion capacity was independently related to the expiratory/inspiratory MLD of the lower lobes and to the inspiratory MLD of the upper lobes.ConclusionsThere are differences in lung attenuation measurements by HRCT between the varying levels of COPD severity as assessed by the GOLD scale(AU)
Subject(s)
Search on Google
Collection: 06-national / ES Database: IBECS Main subject: Plethysmography / Respiratory Function Tests / Spirometry / Pulmonary Disease, Chronic Obstructive Type of study: Prognostic_studies / Risk_factors_studies Limits: Humans / Male Language: Es Journal: Arch. bronconeumol. (Ed. impr.) Year: 2010 Document type: Article
Search on Google
Collection: 06-national / ES Database: IBECS Main subject: Plethysmography / Respiratory Function Tests / Spirometry / Pulmonary Disease, Chronic Obstructive Type of study: Prognostic_studies / Risk_factors_studies Limits: Humans / Male Language: Es Journal: Arch. bronconeumol. (Ed. impr.) Year: 2010 Document type: Article