Comparison of relative renal function measured with either 99mTc-DTPA or 99mTc-EC dynamic scintigraphies with that measured with 99mTc-DMSA static scintigraphy
Domingues, F. C; Fujikawa, G. Y; Decker, H; Alonso, G; Pereira, J. C; Duarte, P. S.
Affiliation
  • Domingues, F. C; University of Sao Paulo. Health Public School. Department of Epidemiology. Section of Nuclear Medicine, Fleury Diagnostic Center. Sao Paulo. BR
  • Fujikawa, G. Y; University of Sao Paulo. Health Public School. Department of Epidemiology. Section of Nuclear Medicine, Fleury Diagnostic Center. Sao Paulo. BR
  • Decker, H; University of Sao Paulo. Health Public School. Department of Epidemiology. Section of Nuclear Medicine, Fleury Diagnostic Center. Sao Paulo. BR
  • Alonso, G; University of Sao Paulo. Health Public School. Department of Epidemiology. Section of Nuclear Medicine, Fleury Diagnostic Center. Sao Paulo. BR
  • Pereira, J. C; University of Sao Paulo. Health Public School. Department of Epidemiology. Section of Nuclear Medicine, Fleury Diagnostic Center. Sao Paulo. BR
  • Duarte, P. S; University of Sao Paulo. Health Public School. Department of Epidemiology. Section of Nuclear Medicine, Fleury Diagnostic Center. Sao Paulo. BR
Int. braz. j. urol ; 32(4): 405-409, July-Aug. 2006. ilus, tab
Article in En | LILACS | ID: lil-436883
Responsible library: BR1.1
ABSTRACT

OBJECTIVE:

The aim of this study was to compare the renal function measured with either 99mTc-DTPA or 99mTc-EC dynamic scintigraphies with that measured using 99mTc-DMSA static scintigraphy.

METHODS:

the values of relative renal function measured in 111 renal dynamic scintigraphies performed either with 99mTc-DTPA (55 studies) or with 99mTc-EC (56 studies) were compared with the relative function measured using 99mTc-DMSA static scintigraphy performed within a 1-month period. The comparisons were performed using Wilcoxon signed rank test. The number of 99mTc-DTPA and 99mTc-EC studies that presented relative renal function different by more than 5 percent from that measured with 99mTc-DMSA, using chi square test were also compared.

RESULTS:

the relative renal function measured with 99mTc-EC is not statistically different from that measured with 99mTc-DMSA (p = 0.97). The relative renal function measured with 99mTc-DTPA was statistically different from that measured using 99mTc-DMSA, but with a borderline statistical significance (p = 0.05). The number of studies with relative renal function different by more than 5 percent from that measured with 99mTc-DMSA is higher for the 99mTc-DTPA scintigraphy (p = 0.04) than for 99mTc-EC.

CONCLUSION:

the relative renal function measured with 99mTc-EC dynamic scintigraphy is comparable with that measured with 99mTc-DMSA static scintigraphy, while the relative renal function measured with 99mTc-DTPA dynamic scintigraphy presents a significant statistical difference from that measured with 99mTc-DMSA static scintigraphy.
Subject(s)
Full text: 1 Collection: 01-internacional Database: LILACS Main subject: Renal Artery Obstruction / Radiopharmaceuticals Limits: Adolescent / Adult / Aged / Child / Child, preschool / Female / Humans / Infant / Male / Newborn Language: En Journal: Int. braz. j. urol Journal subject: UROLOGIA Year: 2006 Document type: Article Affiliation country: Brazil
Full text: 1 Collection: 01-internacional Database: LILACS Main subject: Renal Artery Obstruction / Radiopharmaceuticals Limits: Adolescent / Adult / Aged / Child / Child, preschool / Female / Humans / Infant / Male / Newborn Language: En Journal: Int. braz. j. urol Journal subject: UROLOGIA Year: 2006 Document type: Article Affiliation country: Brazil