Confirmación de método de ayuda diagnóstica dela dinámica cardiaca de aplicacción clínica desarrollado con base en la teoría de la probabilidad / Confirmation oftthe methodology of diagnostic aid for the cardiac dynamics for clinical application developed based on the probability theory / Cofirmação do méétodo de ajuda diagnóstica da dinâica cardíaca dee aplicação clínica desenvolvido com base na teoria da probabilidade
RODRÍGUEZ, JAVIER; CORREA, CATALINA; PRIETO, SIGNED; BERNAL, PEDRO; GERMÁN, FORERO; SALAZAR, GABRIEL; VITERY, SARITH; ALVAREZ, LUISA; PUERTA, GERMÁN.
Affiliation
  • RODRÍGUEZ, JAVIER; Centro de Investigaciones Clínica del Country. Grupo Insight. CO
  • CORREA, CATALINA; Centro de Investigaciones Clínica del Country. Grupo Insight. CO
  • PRIETO, SIGNED; Centro de Investigaciones Clínica del Country. Grupo Insight. CO
  • BERNAL, PEDRO; Centro de Investigaciones Clínica del Country. Grupo Insight. CO
  • GERMÁN, FORERO; Centro de Investigaciones Clínica del Country. Grupo Insight. CO
  • SALAZAR, GABRIEL; Centro de Investigaciones Clínica del Country. Grupo Insight. CO
  • VITERY, SARITH; Centro de Investigaciones Clínica del Country. Grupo Insight. CO
  • ALVAREZ, LUISA; Centro de Investigaciones Clínica del Country. Grupo Insight. CO
  • PUERTA, GERMÁN; Centro de Investigaciones Clínica del Country. Grupo Insight. CO
Rev. MED ; 19(2): 167-177, jul.-dic. 2011. tab
Article in Es | LILACS | ID: lil-657114
Responsible library: CO87.1
RESUMEN
A partir de la teoría de probabilidad y los sistemas dinámicos se desarrolló previamente una nueva metodología de ayuda diagnóstica para el Holter con base en la teoría de la probabilidad. El propósito de este trabajo es evaluar su concordancia diagnóstica en casos normales y con enfermedad aguda. Se tomaron 15 Holters normales y 100 con diferentes patologías cardiacas de pacientes mayores a 20 años. Se establecieron rangos de frecuencias cardiacas y de número de latidos por hora y se calculó la probabilidad de estos rangos. Los valores obtenidos se analizaron de acuerdo con los parámetros diagnósticos establecidos en la metodología previamente desarrollada para diferenciar normalidad de enfermedad. Finalmente se evaluó sensibilidad, especificidad y coeficiente Kappa de la evaluación física matemática respecto al diagnóstico convencional para los casos normales y con enfermedad aguda. Los Holter con enfermedad aguda presentaron entre 6 y 13 rangos de frecuencias y los normales entre 13 y 21 rangos. La probabilidad máxima de latidos por hora en normalidad presentó cuatro casos con probabilidad menor o igual a 0,217 o mayor o igual a 0,304, mientras que para enfermedad aguda todos tuvieron valores mayores o iguales a 0,304. De los Holter, 5 con enfermedad aguda, y 2 normales presentaron un número de latidos menor a 3.000. La suma de las probabilidades de las dos frecuencias más probables se encontró entre 0,203 y 0,379 para los normales y entre 0,333 y 0,652 para los Holters con patologías agudas. Los valores de sensibilidad y especificidad fueron de 100% Y 73,3% y el coeficiente Kappa de 0,86. Se confirmó que la metodología desarrollada con base en la teoría de la probabilidad revela una autoorganización del sistema cardiaco que permite diferenciar normalidad de enfermedad aguda y evidenciar la evolución entre ambos a nivel clínico.
ABSTRACT
Starting from the probability theory and dynamic systems, a novel methodology of diagnostic aid for the Holter test was developed previously, based on the probability theory. The aim of this paper is to assess its diagnostic concordance in normal and acutely ill cases. Fifteen normal Holter tests and 100 with different cardiac pathologies from patients older than 20 years were taken. Cardiac rates ranges and number of beats per hour were determined and the probability of theses ranges was estimated. The obtained values were analyzed according to the diagnostic parameters established in the previously developed methodology in order to differentiate the normal status from the disease. Finally, sensitivity, specificity and Kappa coefficient of the physical mathematical evaluation with regard to the conventional diagnosis for normal and acutely ill cases were assessed. The Holter tests with acute disease showed between 6 and 13 ranges of frequencies, and the normal ones between 13 and 21 ranges. The maximum probability of beats per hour in normality presented four cases with probability less then or equal to 0.217 or higher than or equal to 0.304, while for acute disease all had values higher than or equal to 0.304. From among the Holter tests, 5 with acute disease and 2 normal presented a number of beats lower than 3.000. The sum of probabilities of the most probable frequencies was between 0.203 and 0.379 for the normal ones and between 0.333 and 0.652 for the Holter tests with acute pathologies. Sensitivity and specificity values were 100% and 73.3%, and the Kappa coefficient 0.86. It was confirmed that the methodology developed based on the probability theory reveals an autoorganization of the cardiac system which allows to differentiate between normality and acute disease and to evidence the evolution between both at the clinical level.
RESUMO
A partir da teoría de probabilidade e dos sistemas dinâmicos desenvolveu-se previamente uma nova metodologia de ajuda diagnóstica para o Holter com base na teoría da probabilidade. O propósito deste trabalho é avaliar sua concordância diagnóstica em casos normais e com doença aguda. Foram tomados Holters normais e 100 com diferentes patologias cardíacas de pacientes maiores de 20 anos. Estabeleceram-se intervalos de frequências cardíacas e de número de batidas por hora e calculou-se a probabilidade destes intervalos. Os valores obtidos foram analisados de acordo com os parâmetros diagnósticos estabelecidos na metodologia previamente desenvolvida para diferenciar normalidade de doença. Finalmente avaliou-se sensibilidade, especificidade e coeficiente Kappa da avaliação física matemática com respeito ao diagnóstico convencional para os casos normais e com doença aguda. Os Holters com doença aguda apresentaram entre 6 e 13 intervalos de frequências e os normais entre 13 e 21 intervalos. A probabilidade máxima de batidas por hora em normalidade apresentou quatro casos com probabilidade menor ou igual a 0,217 ou maior ou igual a 0,304, enquanto que para doença aguda todos tiveram valores maiores ou iguais que 0,304. Dos Holter, 5 com doença aguda, e 2 normais apresentaram um número de batidas menor que 3.000. A soma das probabilidades das duas frequências mais prováveis foi encontrada entre 0,203 e 0,379 para os normais e entre 0,333 e 0,652 para os Holters com patologias agudas. Os valores de sensibilidade e especificidade foram de 100% e 73,3% e o coeficiente Kappa de 0,86. Confirmou-se que a metodologia desenvolvida com base na teoria da probabilidade revela una autoorganização do sistema cardíaco que permite diferenciar normalidade de doença aguda e evidenciar a evolução entre ambos a nível clínico.
Subject(s)
Key words
Full text: 1 Collection: 01-internacional Database: LILACS Main subject: Electrocardiography, Ambulatory Type of study: Diagnostic_studies Limits: Humans Language: Es Journal: Rev. MED Journal subject: MEDICINA Year: 2011 Document type: Article Affiliation country: Colombia Country of publication: Colombia
Full text: 1 Collection: 01-internacional Database: LILACS Main subject: Electrocardiography, Ambulatory Type of study: Diagnostic_studies Limits: Humans Language: Es Journal: Rev. MED Journal subject: MEDICINA Year: 2011 Document type: Article Affiliation country: Colombia Country of publication: Colombia