Contaminación bacteriana en el agua de unidades dentales de una institución de salud pública / Bacterial contamination in dental unit water from a public health institution
Acta odontol. venez
; 49(1)2011. tab
Article
in Es
| LILACS
| ID: lil-678867
Responsible library:
VE1.1
RESUMEN
Se evaluó la calidad bacteriológica del agua de 8 clínicas de una institución de salud pública (ISSSTE) de 2 zonas de la ciudad de México, determinándose coliformes fecales y coliformes totales, por medio de la técnica de filtro de membrana, realizándose en 2 diferentes periodos y 3 puntos de muestreo (jeringa triple, llena vasos y suministro) en 9 unidades dentales. De las 8 clínicas analizadas 7 presentaron contaminación bacteriana. Perteneciendo 4 a la zona norte y 3 a la zona sur. El problema de la contaminación en la zona norte se debe principalmente a la mala calidad del agua de suministro la cual en esta zona provenía en su mayoría de las botellas del sistema abastecedor de agua. La otra causa de contaminación se debió a la deficiente o nula desinfección de la jeringa triple. En la zona sur 3 de las 4 clínicas en general presentaron baja contaminación bacteriana solo en el primer periodo, lo cual se puede atribuir a la mejor calidad del agua proveniente de los suministros. Se concluye que los factores determinantes de la presencia de contaminación bacteriana en el agua utilizada en las unidades dentales de ambas zonas fueron la calidad del agua de suministro y la inadecuada desinfección de la jeringa triple. Mantener una buena calidad de agua en las unidades dentales es muy importante, pues el líquido entra directamente en contacto con la mucosa de cavidad oral, estructuras dentarias, sangre y saliva del paciente, evitando procesos infecciosos que podrían poner en riesgo su salud integral
ABSTRACT
It was assessed the bacteriological quality of water in 8 clinics of a public health institution (ISSSTE) in 2 areas of Mexico City, determined fecal coliform and total coliform, by means of the technique of membrane filter. There were made 2 different periods and 3 sampling points (syringe triple, flood glasses and supply) in 9 dental units. Of the 8 clinics analyzed 7 presented bacterial pollution. 4 Belonged to the north and 3 to the south zone. The problem of pollution in the north zone is mainly due to the poor water quality of supply which in this area came mostly from the bottles of the flush system. The other source of pollution was due to the poor or non-existent disinfection of the triple syringe. In the south zone in general 3 of 4 clinics presented low bacterial pollution only in the first period, which can be attributed to the better quality of water from the supplies. It concludes that the determining factors in the presence of bacterial pollution in water used in dental units of both areas were the quality of water supply and inadequate disinfection of the triple syringe. Maintain a good water quality in dental units is very important, because liquid makes direct contact with the mucous membrane of oral cavity, dental structures, blood and saliva of the patient, avoiding infectious processes that could put in risk their integral health
Key words
Full text:
1
Collection:
01-internacional
Database:
LILACS
Main subject:
Water Pollution
/
Dental Offices
Type of study:
Evaluation_studies
Language:
Es
Journal:
Acta odontol. venez
Journal subject:
Medicina Bucal
/
ODONTOLOGIA
/
Sa£de Bucal
Year:
2011
Document type:
Article
Affiliation country:
Mexico
Country of publication:
Venezuela