Your browser doesn't support javascript.
loading
Análise crítica com TCFC da altura e espessura em sítios maxilares edêntulos potenciais para implantes dentários, usando-se a técnica all-on-four: estudo piloto / A critical CBCT analysis of height and thickness in edentulous maxillary potential implant sites regarding the all-on-four technique: pilot study
Reis, Maria Cecília Sucupira dos; Safira, Lucio Costa; Francischone, Carlos Eduardo; Mendonça, Robson G; Wendell, Sérgio; Freitas, André Carlos de; Duarte, Luis Rogério.
Affiliation
  • Reis, Maria Cecília Sucupira dos; UFBA. BR
  • Safira, Lucio Costa; SL Mandic. BR
  • Francischone, Carlos Eduardo; SL Mandic. BR
  • Mendonça, Robson G; UFBA. BR
  • Wendell, Sérgio; UFBA. BR
  • Freitas, André Carlos de; UFBA. BR
  • Duarte, Luis Rogério; UFBA. BR
ImplantNews ; 10(6a): 105-110, 2013. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-761254
Responsible library: BR243.1
RESUMO
A técnica da cirurgia guiada sem retalho representa um grande avanço tecnológico, e é considerada uma realidade na Osseointegração. Sendo assim, a sua execução deve seguir alguns cuidados para o sucesso no tratamento proposto, no que tange alguns aspectos essenciais, a exemplo da disponibilidade óssea mínima para correta instalação dos implantes. Portanto, foi realizado um estudo tomográfico com amostra de 20 maxilas totalmente edêntulas para avaliar a viabilidade da instalação virtual de implantes no software Dental Slice, de acordo com a disponibilidade óssea, seguindo o protocolo all-on-four, além de mensurar nos cortes tomográficos a altura e a espessura dos sítios de instalação dos implantes. Os resultados encontrados de acordo com a análise estatística foram 5% das maxilas estudadas apresentaram disponibilidade suficiente para a inserção completa dos quatro implantes no osso remanescente; 95% das maxilas apresentaram áreas de fenestrações ou ausência completa de possibilidade de inserção. Nos 80 sítios de instalação de implantes mensurados foram encontradas médias de 8,58 mm (p=0,66) e de 3,52 mm (p=0,85) de altura e de espessura óssea, respectivamente. Os autores concluem que apenas 5% das 20 maxilas estudadas foram consideradas viáveis para a inserção completa de implantes seguindo o protocolo all-on-four...
ABSTRACT
Guided flapless surgery has proved to be a major breakthrough in the practice of Implantodontics, but certain precautions should be taken in the execution of this technique, particularly with respect to the minimum availability of bone required for the successful implant placement. With this in mind, a tomographic study of 20 completely edentulous maxillae was carried out using Dental Slice software, to measure the bone height and thickness of potential implant insertion sites and evaluate the viability of installing implants following an ‘All-on-four’ protocol. A total of 80 sites were evaluated and a mean height of 8.58mm (p= 0.66) and a mean thickness of 3.52 mm (p= 0.85) were recorded. Statistical analysis of the results showed that only 5% of the maxillae studied had suffi cient remaining bone for the complete insertion of four implants, while 95% either presented areas of fenestration or were completely inadequate for implant placement. It was concluded that complete implant insertion following an ‘All-on-four’ protocol was viable in only 5% of studied cases...
Subject(s)

Search on Google
Collection: International databases Database: LILACS Main subject: Dental Implants / Osseointegration / Jaw, Edentulous / Cone-Beam Computed Tomography Type of study: Practice guideline Limits: Humans Language: Portuguese Journal: ImplantNews Journal subject: Dentistry Year: 2013 Document type: Article Affiliation country: Brazil Institution/Affiliation country: SL Mandic/BR / UFBA/BR
Search on Google
Collection: International databases Database: LILACS Main subject: Dental Implants / Osseointegration / Jaw, Edentulous / Cone-Beam Computed Tomography Type of study: Practice guideline Limits: Humans Language: Portuguese Journal: ImplantNews Journal subject: Dentistry Year: 2013 Document type: Article Affiliation country: Brazil Institution/Affiliation country: SL Mandic/BR / UFBA/BR
...