New formulation metered dose inhaler increases breath alcohol levels.
Barry, P W; O'Callaghan, C.
Affiliation
  • Barry PW; Department of Child Health, University of Leicester, U.K.
Respir Med ; 93(3): 167-8, 1999 Mar.
Article in En | MEDLINE | ID: mdl-10464872
ABSTRACT
A new, chlorofluorocarbon-free metered dose inhaler containing salbutamol, with small amounts of ethanol as a co-solvent, has recently been released. We evaluated the effect on breath alcohol levels of two inhalations from this metered dose inhaler. In 10 volunteers, breath alcohol levels rose to 17.9 micrograms 100 ml-1 breath after an inhalation with a good technique, and to 35 micrograms 100 ml-1 breath (the current legal limit for driving in the UK) after a poor inhalation. Breath alcohol levels were reduced by the use of a spacer device, and in all cases fell to near zero after 2 min. In patients who have just used this type of metered dose inhaler, breath alcohol measurements should be defferred for at least 2 min.
Subject(s)
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Nebulizers and Vaporizers / Chlorofluorocarbons / Ethanol Limits: Adult / Humans Language: En Journal: Respir Med Year: 1999 Document type: Article Affiliation country: United kingdom