Your browser doesn't support javascript.
loading
The contribution of cortical and cancellous bone to dual-energy X-ray absorptiometry measurements in the female proximal femur.
Lundeen, G A; Knecht, S L; Vajda, E G; Bloebaum, R D; Hofmann, A A.
Affiliation
  • Lundeen GA; Bone and Joint Research Laboratory, Department of Veterans Affairs, Salt Lake City Health Care System, 500 Foothill Boulevard, Salt Lake City, UT 84148, USA.
Osteoporos Int ; 12(3): 192-8, 2001.
Article in En | MEDLINE | ID: mdl-11315237
ABSTRACT
Dual-energy X-ray absorptiometry (DXA) is the most common method for determining bone mineral density (BMD) in the proximal femur. However, there remain questions concerning the contribution of cortical and cancellous bone to this technology in the proximal femur. The purpose of this investigation was to identify structural and compositional characteristics of human bone in the proximal femur that significantly influence DXA BMD measurements. Twenty-four femora were obtained at autopsy from Caucasian females ranging in age from 17 to 92 years (mean +/- SD, 61 +/- 25 years). DXA scans were performed on each specimen with a Hologic QDR-2000 densitometer. Direct measurements were determined from proximal femoral sections for cancellous bone (volume fraction, ash fraction, cancellous cross-sectional area and percent cancellous cross-sectional area), cortical bone (thickness, ash fraction, porosity, cortical cross-sectional area and percent cortical cross-sectional area) and anteroposterior thickness. These parameters were compared with the associated DXA measurements by means of simple and multiple regressions. Cancellous volume fraction was the best predictor of variability of DXA measurements for both the neck and trochanter, with an R2 of 0.87 and 0.76, respectively (p < 0.0001). There was only a minor influence of cortical factors such as thickness (neck and trochanter R2 = 0.51 and 0.42, respectively, p < 0.001) and trochanteric cross-sectional area (R2 = 0.21, p < 0.05). Although the accuracy for determining specific components of the proximal femur was low, the DXA BMD measurement was a strong predictor of cancellous bone factors, but not cortical bone factors that have been shown to change significantly with age.
Subject(s)
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Bone Density / Femur Type of study: Prognostic_studies Limits: Adolescent / Adult / Aged / Aged80 / Female / Humans / Middle aged Language: En Journal: Osteoporos Int Journal subject: METABOLISMO / ORTOPEDIA Year: 2001 Document type: Article Affiliation country: United States
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Bone Density / Femur Type of study: Prognostic_studies Limits: Adolescent / Adult / Aged / Aged80 / Female / Humans / Middle aged Language: En Journal: Osteoporos Int Journal subject: METABOLISMO / ORTOPEDIA Year: 2001 Document type: Article Affiliation country: United States