OBJECTIVE: To evaluate the technical feasibility of a new monorail-stent-balloon device for treatment of renal artery stenosis (RAS). PATIENTS AND METHODS: During a study period of 18 months, 38 patients with proven RAS in 41 cases (hypertension n = 36, renal insufficiency n = 13) and indication for stenting (calicified ostial lesions n = 35, insufficient PTA n = 4, dissection n = 2) were enrolled into this prospective evaluation. Pre-mounted stents (Rx-Herculink(TM) 5 mm = 13, 6 mm = 34, 7 mm = 1) were implanted a transfemoral (n = 35) or transbrachial approach (n = 6). Mean grade and lengths of stenosis measured were 88 % plus minus 10 and 9 mm plus minus 5. RESULTS: Renal stent implantation was technically successful in all cases (100 %). In 7 cases a second stent had to be implanted to cover the entire lesion. The transstenotic pressure drop decreased from 88 mmHg plus minus 10 before to 1 mmHg plus minus 1.8 after the procedure. Remaining stenosis measured 0.7 % plus minus 4.2. Serum creatine levels decreased from 1.9 mm/dl to 1.5 mg/dl (n. s.), blood pressure decreased from 178/94 mmHg to 148/79 mmHg (p < 0.0001) after the intervention. Primary and secondary patency rates at 6 months were 72 % (Standard Error 9.8 %) and 77 (% (Standard Error 9.2 %), respectively. CONCLUSION: With the used monorail-stend-balloon device a technically easy, secure and exact renal stent placement is guaranteed, patency rates are similar to those described in the current literature.
Subject(s)
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Renal Artery Obstruction / Catheterization / Stents Type of study: Diagnostic_studies / Evaluation_studies / Observational_studies / Prognostic_studies Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: De Journal: Rofo Year: 2002 Document type: Article Affiliation country: Germany Country of publication: Germany
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Renal Artery Obstruction / Catheterization / Stents Type of study: Diagnostic_studies / Evaluation_studies / Observational_studies / Prognostic_studies Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: De Journal: Rofo Year: 2002 Document type: Article Affiliation country: Germany Country of publication: Germany