Low-cost failure sensor design and development for water pipeline distribution systems.
Water Sci Technol
; 45(4-5): 207-15, 2002.
Article
in En
| MEDLINE
| ID: mdl-11936636
This paper describes the design and development of a new sensor which is low cost to manufacture and install and is reliable in operation with sufficient accuracy, resolution and repeatability for use in newly developed systems for pipeline monitoring and leakage detection. To provide an appropriate signal, the concept of a "failure" sensor is introduced, in which the output is not necessarily proportional to the input, but is unmistakably affected when an unusual event occurs. The design of this failure sensor is based on the water opacity which can be indicative of an unusual event in a water distribution network. The laboratory work and field trials necessary to design and prove out this type of failure sensor are described here. It is concluded that a low-cost failure sensor of this type has good potential for use in a comprehensive water monitoring and management system based on Artificial Neural Networks (ANN).
Search on Google
Collection:
01-internacional
Database:
MEDLINE
Main subject:
Water Pollutants
/
Water Supply
Type of study:
Diagnostic_studies
/
Health_economic_evaluation
Language:
En
Journal:
Water Sci Technol
Journal subject:
SAUDE AMBIENTAL
/
TOXICOLOGIA
Year:
2002
Document type:
Article
Country of publication:
United kingdom