ABSTRACT

OBJECTIVE:

This study evaluated the perioperative and 3-year follow-up results of 103 consecutive carotid artery stenting (CAS) procedures done with a transcervical approach using carotid flow reversal for cerebral protection that were performed over a 28-month period in 97 patients.

METHODS:

The mean age of these patients was 72 years, and 82 (80%) were men. Mean preoperative internal carotid artery (ICA) peak systolic velocity was 314 cm/s, 36% of treated hemispheres were symptomatic, and 42% of patients had neurologic symptoms for >6 months. Ten patients (10%) had contralateral ICA occlusion, six (6%) had recurrent carotid stenosis, and two (2%) had previous neck radiation. Local anesthesia was used in 72 (70%) cases and general in 31 (30%). Predilatation was used in 34 cases (33%), and closed-cell self-expanding stents were deployed and postdilated in all cases.

RESULTS:

Technical success was achieved in 100 cases (97%). No major strokes or deaths occurred. One ipsilateral transient ischemic attack (1%), one contralateral transient ischemic attack (1%), and two minor strokes (2%) occurred. There were two wound complications (2%) and one major arterial complication (1%). Mean operative time was 69 minutes, and mean carotid flow reversal time was 21 minutes. Three awake patients (4%) did not tolerate carotid flow reversal. Hypotension/bradycardia occurred in 24 cases (23%). No electrocardiographic myocardial infarctions were diagnosed. At 40 months of follow-up, the stent patency rate on an intention-to-treat basis was 95%, and the stroke-free survival was 91%.

CONCLUSIONS:

Transcervical CAS with carotid flow reversal can be done with a high rate of technical success, a negligible rate of major adverse events, and an excellent 3-year stroke-free survival and stent patency rate. These results compare favorably with those of recently published prospective studies using distal filter protection during CAS.
Subject(s)
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Arteriovenous Shunt, Surgical / Carotid Stenosis / Angioplasty, Balloon Type of study: Observational_studies / Prognostic_studies Limits: Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: J Vasc Surg Journal subject: ANGIOLOGIA Year: 2007 Document type: Article Affiliation country: United States
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Arteriovenous Shunt, Surgical / Carotid Stenosis / Angioplasty, Balloon Type of study: Observational_studies / Prognostic_studies Limits: Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: J Vasc Surg Journal subject: ANGIOLOGIA Year: 2007 Document type: Article Affiliation country: United States