Your browser doesn't support javascript.
loading
Can protons improve SBRT for lung lesions? Dosimetric considerations.
Georg, Dietmar; Hillbrand, Martin; Stock, Markus; Dieckmann, Karin; Pötter, Richard.
Affiliation
  • Georg D; Department of Radiotherapy, Medical University Vienna/AKH Vienna, Vienna, Austria. Dietmar.Georg@akhwien.at
Radiother Oncol ; 88(3): 368-75, 2008 Sep.
Article in En | MEDLINE | ID: mdl-18405986
ABSTRACT
BACKGROUND AND

PURPOSE:

The aim of the present study was to investigate potential dosimetric benefits of proton therapy for hypofractionated stereotactic body radiotherapy (SBRT). MATERIALS AND

METHOD:

Twelve patients undergoing hypofractionated SBRT at the Medical University Vienna were selected. Passively scattered protons (PT) and intensity modulated proton therapy (IMPT) were evaluated against a conformal photon technique (3D-CRT), assuming a fractionation of 3x15Gy, prescribed to the 65% isodose. For all treatment techniques shallow breathing with abdominal compression (SB+AC) was compared with a deep inspiration breath hold technique (DIBH). Treatment planning was done with XiO (CMS, USA). Target conformity, dose-volume histograms (DVH) and various associated dosimetric parameters were considered for the planning target volume (PTV), lung, heart and esophagus.

RESULTS:

For both breathing conditions conformity indices were very similar. They were between 0.75 and 0.78 for IMPT and 3D-CRT and around 0.55 for PT using 2-3 beams. Irrespective of treatment modality, DVHs for the ipsilateral lung were improved with the DIBH technique. For the PT technique, the 2Gy isodose (V2Gy) covered on average 7-9% less lung volume compared to 3D-CRT, for IMPT this reduction was more than 10%. Volumes covered the 4 and 6Gy isodoses were 2-4% smaller for IMPT, but very similar for PT and 3D-CRT. Both proton techniques achieved full sparing of the contralateral lung and superior sparing of the heart. Maximum doses to the heart and esophagus were on average around 3Gy for 3D-CRT and almost 0Gy for both proton techniques. For 3D-CRT average V2Gy values for the heart could be reduced from 64% in shallow breathing to 34% in DIBH. V2Gy for protons was negligible.

CONCLUSIONS:

Only small dosimetric differences were found between photons and protons for SBRT of lung lesions. Whether these small dosimetric benefits translate in reduced side effects or have the potential to improve local control rates remains to be demonstrated in clinical studies.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Radiotherapy Dosage / Radiosurgery / Radiotherapy, Intensity-Modulated / Proton Therapy / Lung Neoplasms Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: Radiother Oncol Year: 2008 Document type: Article Affiliation country: Austria

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Radiotherapy Dosage / Radiosurgery / Radiotherapy, Intensity-Modulated / Proton Therapy / Lung Neoplasms Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: Radiother Oncol Year: 2008 Document type: Article Affiliation country: Austria