Your browser doesn't support javascript.
loading
Transmissive x-ray beam position monitors with submicron position- and submillisecond time resolution.
Rev Sci Instrum ; 79(6): 063103, 2008 Jun.
Article in En | MEDLINE | ID: mdl-18601393
ABSTRACT
We present the development of fast transmissive center-of-mass x-ray beam position monitors with a large active area, based on a thinned position sensitive detector in both a duo- and a tetra-lateral variant. The detectors were tested at BESSY beamlines BL14.1, KMC-1, and KMC-2 and yielded signal currents of up to 3 microA/100 mA ring current at 10 keV photon energy using the monochromatic focused beam of BL14.1. The active area sizes were 1 x 1 and 3 x 3 mm(2) for the duo-lateral and 5 x 5 mm(2) for the tetra-lateral devices, with the duo-lateral detectors currently being available in sizes from 1 x 1 to 10 x 10 mm(2) and thicknesses between 5 and 10 microm. The presented detectors' thicknesses were measured to be 5 and 8 microm with a corresponding transmission of up to 93% at 10 keV and 15% at 2.5 keV. Up to a detection bandwidth of 10 kHz, the monitors provide submicron position resolution. For lower detection bandwidths, the signal-to-noise reaches values of up to 6 x 10(4) at 10 Hz, corresponding to a position resolution of better than 50 nm for both detector sizes. As it stands, this monitor design approach promises to be a generic solution for automation of state-of-the-art crystal monochromator beamlines.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: X-Rays / Photons / Crystallography, X-Ray / Electrons Language: En Journal: Rev Sci Instrum Year: 2008 Document type: Article Affiliation country: Germany

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: X-Rays / Photons / Crystallography, X-Ray / Electrons Language: En Journal: Rev Sci Instrum Year: 2008 Document type: Article Affiliation country: Germany