Your browser doesn't support javascript.
loading
First experience with real-time three-dimensional transoesophageal echocardiography-guided transseptal in patients undergoing atrial fibrillation ablation.
Chierchia, Gian Battista; Capulzini, Lucio; de Asmundis, Carlo; Sarkozy, Andrea; Roos, Markus; Paparella, Gaetano; Boussy, Tim; Van Camp, Guy; Kerkhove, Dirk; Brugada, Pedro.
Affiliation
  • Chierchia GB; 1Cardiology Department, Heart Rhythm Management Center, UZ Brussel, Vrije Universiteit Brussel, Brussels, Belgium. jeanbaptiste.chierchia@uzbrussel.be
Europace ; 10(11): 1325-8, 2008 Nov.
Article in En | MEDLINE | ID: mdl-18835940
ABSTRACT

AIMS:

Transseptal (TS) puncture during atrial fibrillation (AF) ablation is a relatively safe procedure in experienced hands. However, major and minor complications cannot be completely ruled out. Real-time three-dimensional transeosophageal echocardiography (RT 3D TEE) is a novel imaging technology that permits direct visualization of the fossa ovalis in a 3D perspective, thereby sensibly lowering the likelihood of potential adverse effects during TS. In our study, we describe the technique and assess the feasibility, advantages, and safety of this novel imaging method in guiding TS puncture in a series of consecutive patients undergoing AF ablation. METHODS AND

RESULTS:

We performed TS puncture guided by RT 3D TEE under general anaesthesia in 24 consecutive patients (16 male, 55.4 +/- 8.1 years) undergoing ablation for drug refractory AF. The fossa ovalis could clearly be seen and easily be distinguished from surrounding anatomical structures in all 24 patients. All punctures required a single attempt to access left atrium. Mean orientation of the needle hub when puncturing was 4.30 o'clock (ranging from 3 o'clock to 6.30 o'clock), and mean distances from the needle tip to the aortic and to the posterior wall were, respectively, 13.5 +/- 7 and 35 +/- 7.3 mm. Total fluoroscopic time was 120.6 +/- 34 s. No major or minor complications were experienced.

CONCLUSION:

Real-time three-dimensional transeosophageal is a very useful tool in guiding TS puncture in patients undergoing AF ablation with the invaluable advantage of the 3D direct visualization of the fossa ovalis. This permits fast and safe transatrial access with a single puncture attempt.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Atrial Fibrillation / Punctures / Echocardiography, Transesophageal / Echocardiography, Three-Dimensional / Surgery, Computer-Assisted / Heart Septum Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: Europace Journal subject: CARDIOLOGIA / FISIOLOGIA Year: 2008 Document type: Article Affiliation country: Belgium

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Atrial Fibrillation / Punctures / Echocardiography, Transesophageal / Echocardiography, Three-Dimensional / Surgery, Computer-Assisted / Heart Septum Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: Europace Journal subject: CARDIOLOGIA / FISIOLOGIA Year: 2008 Document type: Article Affiliation country: Belgium