[Efficacy and safety of argon plasma coagulation in the treatment of obstructive tracheobronchial stenosis].
Jin, Fa-guang; Mu, De-guang; Chu, Dong-ling; Fu, En-qing; Xie, Yong-hong; Liu, Tong-gang; Gu, Xing.
Affiliation
  • Jin FG; Department of Respiratory Diseases, Tangdu Hospital, Fourth Military Medical University, Xi'an, China.
Zhonghua Zhong Liu Za Zhi ; 30(6): 462-4, 2008 Jun.
Article in Zh | MEDLINE | ID: mdl-19024524
ABSTRACT

OBJECTIVE:

To evaluate the efficacy and safety of argon plasma coagulation (APC) in the treatment of large airway obstruction.

METHODS:

Totally 389 patients with treacheobronchial stenosis were treated with APC (ARCO3000 type) by bronchoscopy. The stenoses were caused by carcinomas (203 cases, 52.2%), metastatic tumors (67 cases, 17.2%), benign tumors (18 cases, 4.6%), granulomas (93 cases, 23.9%) and other lesions (8 cases, 2.1%). The rate of recanalization, relief of the symptoms, and complications were analyzed.

RESULTS:

1121 times of APC treatment were performed in the 389 patients. Complete recanalization was achieved in 138 cases (35.5%), partial in 143 (36.8%), mild in 55 (14.1%) and none in 53 (13.6%). The major complications included super-ventricular tachycardia in 136 cases (34.9%), bleeding in 51 (13.1%), decrease in blood oxygen saturation in 48 (12.3%), asphyxia in 33 (8.5%), ventricular or super-ventricular arrhythmia in 24 (6.2%), short-term aggravation of airway obstruction in 18 (4.6%), and tracheal perforation in 3 (0.78%). All those complications were treated with various measures and no patient died of the complications during the procedure.

CONCLUSION:

Argon plasma coagulation is effective and relatively safe in relieving the obstruction and dyspnea in patients with large airway obstruction caused by various reasons. However, for the patients with severe airway obstruction, argon plasma coagulation sometimes may cause severe or even lethal complications. Critical consideration of the indication, operators' skill and taking more precautions during the procedure are required to ensure the safety of argon plasma coagulation treatment.
Subject(s)
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Argon / Tracheal Stenosis / Bronchial Diseases / Tracheal Neoplasms / Electrocoagulation Type of study: Etiology_studies / Evaluation_studies / Observational_studies / Risk_factors_studies Limits: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: Zh Journal: Zhonghua Zhong Liu Za Zhi Year: 2008 Document type: Article Affiliation country: China
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Argon / Tracheal Stenosis / Bronchial Diseases / Tracheal Neoplasms / Electrocoagulation Type of study: Etiology_studies / Evaluation_studies / Observational_studies / Risk_factors_studies Limits: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: Zh Journal: Zhonghua Zhong Liu Za Zhi Year: 2008 Document type: Article Affiliation country: China