Your browser doesn't support javascript.
loading
Continuous veno-venous hemofiltration with regional citrate anticoagulation: a four-year single-center experience.
Cassina, T; Mauri, R; Engeler, A; Giannini, O.
Affiliation
  • Cassina T; Anesthesia/Intensive Care Unit, Department of Cardiac Anesthesia, Cardiocentro Ticino, Lugano - Switzerland. tiziano.cassina@cardiocentro.org
Int J Artif Organs ; 31(11): 937-43, 2008 Nov.
Article in En | MEDLINE | ID: mdl-19089795
BACKGROUND: Hemofiltration protocols using a citrate-buffered replacement solution offer the advantage of regional anticoagulation and a buffer effect. The role played by such fluids in clinical practice is not yet well established. The risk of electrolytic disorders, acid-base imbalance, or citrate accumulation should be clarified. We report on a renal therapy protocol based on a citrate isonatremic replacement solution. METHOD: We considered all patients needing renal replacement therapy admitted to our cardiovascular intensive care unit between January 2003 and June 2007. A citrate-buffered fluid was delivered in predilution mode to a post-filter ionized calcium target < or = 0.25 mmol/L. Extracorporeal blood flow was set at a constant of 140+/-10 ml/min. Blood calcemia was maintained by a 5% calcium-chloride solution infused into the patient. We recorded the patients' acid-base variables, ionized calcium, daily electrolytes, albumin, urea and filter life-span. RESULTS: We observed 101 consecutive patients out of 2,523; incidence 4%, overall mortality was 57% at ICU discharge. Mean replacement rate was 2,554+/-475 ml/h corresponding to 34+/-5 ml/kg/h. Mean patient ionized calcium level was 1.07+/-0.04 mmo/L, maintained by 13+/-2 ml/h of infused calcium-chloride. All other electrolytes remained in the normal range. The Stewart biophysical approach confirmed a strong anion gap of 3.1+/- 3 meq/L. Acid-base balance showed a buffer effect. Mean filter life-span was 52+/-11 h. CONCLUSION: Renal replacement therapy based on citrate-buffered fluid may be useful in clinical practice. This methodology presented an adequate metabolic control and allowed regional anticoagulation. A sufficient calcium supply was mandatory to avoid hypocalcemia. The small strong ion gap suggested a modest citrate accumulation.
Subject(s)
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Acid-Base Equilibrium / Blood Coagulation / Dialysis Solutions / Hemofiltration / Citric Acid / Anticoagulants Type of study: Guideline Limits: Aged / Aged80 / Humans / Middle aged Language: En Journal: Int J Artif Organs Year: 2008 Document type: Article Country of publication: United States
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Acid-Base Equilibrium / Blood Coagulation / Dialysis Solutions / Hemofiltration / Citric Acid / Anticoagulants Type of study: Guideline Limits: Aged / Aged80 / Humans / Middle aged Language: En Journal: Int J Artif Organs Year: 2008 Document type: Article Country of publication: United States