Your browser doesn't support javascript.
loading
Variation in the rapid shallow breathing index associated with common measurement techniques and conditions.
Patel, Kapil N; Ganatra, Kalpesh D; Bates, Jason H T; Young, Michael P.
Affiliation
  • Patel KN; Division of Pulmonary and Critical Care, University of Vermont College of Medicine, Smith 140, FAHC, 111 Colchester Avenue, Burlington VT 05401, USA.
Respir Care ; 54(11): 1462-6, 2009 Nov.
Article in En | MEDLINE | ID: mdl-19863829
ABSTRACT

BACKGROUND:

The rapid-shallow-breathing index (RSBI) is widely used to evaluate mechanically ventilated patients for weaning and extubation, but it is determined in different clinical centers in a variety of ways, under conditions that are not always comparable. We hypothesized that the value of RSBI may be significantly influenced by common variations in measurement conditions and technique.

METHODS:

Sixty patients eligible for a weaning evaluation after >or=72 hours of mechanical ventilation were studied over 15 months in a medical intensive care unit. RSBI was measured while the patients were on 2 different levels of ventilator support 5 cm H2O continuous positive airway pressure (CPAP) versus T-piece. RSBI was also calculated in 2 different ways using the values of minute ventilation and respiratory rate provided by the digital output of the ventilator, versus values obtained manually with a Wright spirometer. Finally, RSBI was measured at 2 different times of the day.

RESULTS:

RSBI was significantly less when measured on 5 cm H2O CPAP, compared to T-piece the medians and interquartile ranges were 71 (52-88) breaths/min/L versus 90 (59-137) breaths/min/L, respectively (P<.001). There were no significant differences in the value of RSBI obtained using ventilator-derived versus manual measures of the breathing pattern. RSBI was also not significantly different in the morning versus evening measurements.

CONCLUSIONS:

RSBI can be significantly affected by the level of ventilator support, but is relatively unaffected by both the technique used to determine the breathing pattern and the time of day at which it is measured.
Subject(s)
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Respiratory Function Tests / Ventilator Weaning / Respiratory Rate Type of study: Clinical_trials / Guideline / Observational_studies / Risk_factors_studies Limits: Female / Humans / Male / Middle aged Language: En Journal: Respir Care Year: 2009 Document type: Article Affiliation country: United States
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Respiratory Function Tests / Ventilator Weaning / Respiratory Rate Type of study: Clinical_trials / Guideline / Observational_studies / Risk_factors_studies Limits: Female / Humans / Male / Middle aged Language: En Journal: Respir Care Year: 2009 Document type: Article Affiliation country: United States