Your browser doesn't support javascript.
loading
Highly undersampled supraaortic MRA at 3.0 T: initial results with parallel imaging in two directions using a 16-channel neurovascular coil and parallel imaging factors up to 16.
Kukuk, Guido M; Hadizadeh, Dariusch R; Gieseke, Jürgen; von Falkenhausen, Marcus; Böhm, Ingrid; Semrau, Renate; Urbach, Horst; Koscielny, Arne; Verrel, Frauke; Wilhelm, Kai; Schild, Hans H; Willinek, Winfried A.
Affiliation
  • Kukuk GM; Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, 53105 Bonn, Germany. guido.kukuk@ukb.uni-bonn.de
Magn Reson Imaging ; 28(9): 1311-8, 2010 Nov.
Article in En | MEDLINE | ID: mdl-20692783
PURPOSE: To present the feasibility of highly undersampled contrast-enhanced MRA (CE-MRA) of the supraaortic arteries with a 16-channel neurovascular coil at 3.0 T using parallel imaging in two directions with parallel imaging factors (PIF) up to 16. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. In a prospective study, MRA protocols including PIF of 1, 2, 4, 9 and 16 yielding a spatial resolution from 0.81×0.81×1.0 mm(3) to 0.46×.46×0.98 mm(3) were acquired. In 32 examinations, image quality and vascular segments were rated independently by two radiologists. SNR estimations were performed for all MRA protocols. RESULTS: The use of high PIF allowed to shorten acquisition time from 2:09 min down to 1:13 min and to increase the anatomic coverage while maintaining or even increasing spatial resolution down to 0.46×0.46×0.98 mm(3). The larger anatomic coverage that was achieved with the use of high PIF allowed for visualization of vascular structures that were not covered by the standard protocols. Despite the resulting lower SNR using high PIF, image quality was constantly rated to be adequate for diagnosis or better in all cases. CONCLUSION: The use of high PIF yielded diagnostic image quality and allowed to increase the anatomic coverage while maintaining or even improving spatial resolution and shortening the acquisition time.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Arteries / Angiography / Magnetic Resonance Angiography Type of study: Diagnostic_studies / Guideline / Observational_studies Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: Magn Reson Imaging Year: 2010 Document type: Article Affiliation country: Germany Country of publication: Netherlands

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Arteries / Angiography / Magnetic Resonance Angiography Type of study: Diagnostic_studies / Guideline / Observational_studies Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: Magn Reson Imaging Year: 2010 Document type: Article Affiliation country: Germany Country of publication: Netherlands