Abdominal circumference ratio for the diagnosis of intertwin birth weight discordance.
J Perinat Med
; 39(1): 43-6, 2011 01.
Article
in En
| MEDLINE
| ID: mdl-20954854
ABSTRACT
OBJECTIVES:
We assessed the accuracy of predicting severe twin birth weight discordance (>25%) using the estimated fetal weights (EFW) and abdominal circumference (AC) ratio.METHOD:
A cohort of twin gestations underwent ultrasound examinations within two weeks from birth. We focused on the accuracy of EFW and on the diagnosis of severe birth weight discordance by the difference in EFWs and the AC ratio.RESULTS:
The 661 eligible twin pairs included 51 (7.7%) severely discordant pairs. The accuracy of an EFW to predict the actual birth weight was quite poor, with an acceptable specificity (96.4%), but low sensitivity (28.6-40.5%), to detect severely discordant pairs, whereas an AC ratio of 1.3 detected these discordant pairs with sensitivity and specificity of 97.3-100% and 99.6-99.7%, respectively.CONCLUSION:
By comparing EFWs, 59.5-71.4% of discordant pairs >25% are missed, whereas an AC ratio >1.3 would identify almost all cases.
Full text:
1
Collection:
01-internacional
Database:
MEDLINE
Main subject:
Twins
/
Birth Weight
/
Infant, Small for Gestational Age
/
Fetal Weight
/
Waist Circumference
Type of study:
Diagnostic_studies
Limits:
Female
/
Humans
/
Newborn
/
Pregnancy
Language:
En
Journal:
J Perinat Med
Year:
2011
Document type:
Article
Affiliation country:
Portugal