Your browser doesn't support javascript.
loading
Radiobiological characterization of two therapeutic proton beams with different initial energy spectra used at the Institut Curie Proton Therapy Center in Orsay.
Calugaru, Valentin; Nauraye, Catherine; Noël, Georges; Giocanti, Nicole; Favaudon, Vincent; Mégnin-Chanet, Frédérique.
Affiliation
  • Calugaru V; Institut Curie, Centre de Protonthérapie d'Orsay, Orsay, France.
Int J Radiat Oncol Biol Phys ; 81(4): 1136-43, 2011 Nov 15.
Article in En | MEDLINE | ID: mdl-21075549
ABSTRACT

PURPOSE:

Treatment planning in proton therapy uses a generic value for the relative biological efficiency (RBE) of 1.1 throughout the spread-out Bragg peak (SOBP) generated. In this article, we report on the variation of the RBE with depth in the SOBP of the 76- and 201-MeV proton beams used for treatment at the Institut Curie Proton Therapy Center in Orsay. METHODS AND MATERIALS The RBE (relative to (137)Cs γ-rays) of the two modulated proton beams at three positions in the SOBP was determined in two human tumor cells using as endpoints clonogenic cell survival and the incidence of DNA double-strand breaks (DSBs) as measured by pulse-field gel electrophoresis without and with enzymatic treatment to reveal clustered lesions.

RESULTS:

The RBE for induced cell killing by the 76-MeV beam increased with depth in the SOBP. However for the 201-MeV protons, it was close to that for (137)Cs γ-rays and did not vary significantly. The incidence of DSBs and clustered lesions was higher for protons than for (137)Cs γ-rays, but did not depend on the proton energy or the position in the SOBP.

CONCLUSIONS:

Until now, little attention has been paid to the variation of RBE with depth in the SOBP as a function of the nominal energy of the primary proton beam and the molecular nature of the DNA damage. The RBE increase in the 76-MeV SOBP implies that the tumor tissues at the distal end receives a higher biologically equivalent dose than at the proximal end, despite a homogeneous physical dose. This is not the case for the 201-MeV energy beam. The precise determination of the effects of incident beam energy, modulation, and depth in tissues on the linear energy transfer-RBE relationship is essential for treatment planning.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Relative Biological Effectiveness / DNA Damage / DNA, Neoplasm / Linear Energy Transfer / Proton Therapy Limits: Humans Country/Region as subject: Europa Language: En Journal: Int J Radiat Oncol Biol Phys Year: 2011 Document type: Article Affiliation country: France

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Relative Biological Effectiveness / DNA Damage / DNA, Neoplasm / Linear Energy Transfer / Proton Therapy Limits: Humans Country/Region as subject: Europa Language: En Journal: Int J Radiat Oncol Biol Phys Year: 2011 Document type: Article Affiliation country: France