Your browser doesn't support javascript.
loading
Radiopacity evaluation of calcium aluminate cement containing different radiopacifying agents.
Aguilar, Fabiano Gamero; Garcia, Lucas da Fonseca Roberti; Rossetto, Hebert Luis; Pardini, Luiz Carlos; Pires-de-Souza, Fernanda de Carvalho Panzeri.
Affiliation
  • Aguilar FG; Department of Dental Materials and Prosthodontics, Ribeirão Preto School of Dentistry, University of São Paulo, Ribeirão Preto, SP, Brazil.
J Endod ; 37(1): 67-71, 2011 Jan.
Article in En | MEDLINE | ID: mdl-21146080
ABSTRACT

INTRODUCTION:

The aim of this study was to evaluate the radiopacity of calcium aluminate cement (EndoBinder) with 3 different radiopacifiers (bismuth oxide, zinc oxide, or zirconium oxide) in comparison with gray mineral trioxide aggregate (GMTA), white MTA, and dental structures (enamel and dentin).

METHODS:

Eighteen test specimens of each cement with thicknesses of 0.5, 1.0, 1.5, 2.0, 2.5, and 3.0 mm (n = 3) were made by using a stainless steel matrix and were adapted to a standardizing device (8 × 7 cm) with a graduated aluminum stepwedge varying from 2.0-16.0 mm in thickness. To compare the radiopacity of the cements with that of dental structures, slices of first molars with a thickness increasing from 0.5-3.0 mm were obtained and placed on the standardizing device. One occlusal radiograph for each tested cement was taken, with exposure time of 0.1 seconds and focus-film distance of 20 cm. Films were processed in an automatic device, and the mean radiopacity values were obtained by using a photodensitometer.

RESULTS:

Mean values showed that the thicker the specimen was, the greater was its radiopacity. Only EndoBinder + bismuth oxide (EBBO) and GMTA demonstrated radiopacity values greater than 3.0 mm of the aluminum scale for all thicknesses. When zinc oxide was used as radiopacifier agent, EndoBinder only reached the desired radiopacity with a thickness of 2.0 mm, and with zirconium oxide it was 2.5 mm.

CONCLUSIONS:

Bismuth oxide was the most efficient radiopacifier for EndoBinder, providing adequate radiopacity in all studied thicknesses, as recommended by ISO 6876, being similar to GMTA.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Root Canal Filling Materials / Calcium Compounds / Aluminum Compounds / Contrast Media / Dental Cements / Dental Enamel / Dentin Limits: Humans Language: En Journal: J Endod Year: 2011 Document type: Article Affiliation country: Brazil

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Root Canal Filling Materials / Calcium Compounds / Aluminum Compounds / Contrast Media / Dental Cements / Dental Enamel / Dentin Limits: Humans Language: En Journal: J Endod Year: 2011 Document type: Article Affiliation country: Brazil