MicroCT morphometry analysis of mouse cancellous bone: intra- and inter-system reproducibility.
Verdelis, K; Lukashova, L; Atti, E; Mayer-Kuckuk, P; Peterson, M G E; Tetradis, S; Boskey, A L; van der Meulen, M C H.
Affiliation
  • Verdelis K; Mineralized Tissues Laboratory, The Hospital for Special Surgery, New York, NY, USA. kv100@pitt.edu
Bone ; 49(3): 580-7, 2011 Sep.
Article in En | MEDLINE | ID: mdl-21621659
ABSTRACT
The agreement between measurements and the relative performance reproducibility among different microcomputed tomography (microCT) systems, especially at voxel sizes close to the limit of the instruments, is not known. To compare this reproducibility 3D morphometric analyses of mouse cancellous bone from distal femoral epiphyses were performed using three different ex vivo microCT systems GE eXplore Locus SP, Scanco µCT35 and Skyscan 1172. Scans were completed in triplicate at 12 µm and 8 µm voxel sizes and morphometry measurements, from which relative values and dependence on voxel size were examined. Global and individual visually assessed thresholds were compared. Variability from repeated scans at 12 µm voxel size was also examined. Bone volume fraction and trabecular separation values were similar, while values for relative bone surface, trabecular thickness and number varied significantly across the three systems. The greatest differences were measured in trabecular thickness (up to 236%) and number (up to 218%). The relative dependence of measurements on voxel size was highly variable for the trabecular number (from 0% to 20% relative difference between measurements from 12 µm and 8 µm voxel size scans, depending on the system). The intra-system reproducibility of all trabecular measurements was also highly variable across the systems and improved for BV/TV in all the systems when a smaller voxel size was used. It improved using a smaller voxel size in all the other parameters examined for the Scanco system, but not consistently so for the GE or the Skyscan system. Our results indicate trabecular morphometry measurements should not be directly compared across microCT systems. In addition, the conditions, including voxel size, for trabecular morphometry studies in mouse bone should be chosen based on the specific microCT system and the measurements of main interest.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Imaging, Three-Dimensional / X-Ray Microtomography / Femur Limits: Animals Language: En Journal: Bone Journal subject: METABOLISMO / ORTOPEDIA Year: 2011 Document type: Article Affiliation country: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Imaging, Three-Dimensional / X-Ray Microtomography / Femur Limits: Animals Language: En Journal: Bone Journal subject: METABOLISMO / ORTOPEDIA Year: 2011 Document type: Article Affiliation country: United States