Retrospective comparison of titanium elastic nail (TEN) and reconstruction plate repair of displaced midshaft clavicular fractures.
Chen, Yun-Feng; Wei, Hai-Feng; Zhang, Chi; Zeng, Bing-Fang; Zhang, Chang-Qing; Xue, Jian-Feng; Xie, Xue-Tao; Lu, Ye.
Affiliation
  • Chen YF; Department of Orthopaedic Surgery, Shanghai Sixth People's Hospital, Shanghai Jiaotong University, Shanghai, China.
J Shoulder Elbow Surg ; 21(4): 495-501, 2012 Apr.
Article in En | MEDLINE | ID: mdl-21641826
ABSTRACT

BACKGROUND:

Titanium elastic nails (TENs) are commonly used to repair displaced midshaft clavicular fractures. Although several clinical studies have shown that the use of TENs is more effective and less invasive than traditional plate fixation, high rates of complications associated with TENs have been reported. This retrospective study compared the use of TENs with reconstruction plates in the treatment of displaced midshaft clavicular fractures. MATERIALS AND

METHODS:

From January 2005 to July 2007, 141 patients with displaced midshaft clavicular fractures were treated with TEN or plate fixation. At 6 and 24 months postoperatively, we evaluated the patients' general health, operative complications, and functional recovery.

RESULTS:

The mean bone union time of TEN patients was 12.4 ± 3.4 weeks, whereas that in the plate group was 14.4 ± 3.7 weeks. The time of union was significantly shorter in the TEN group than that in the plate group. There was no significant difference between these 2 groups' rates of complications such as nonunion or malunion. Shoulder function scores were significantly better in the TEN group than in the plate group at 6 months postoperatively. There was no significant difference at 24 months postoperatively. Patients were more satisfied with the cosmetic appearance and overall outcome after TEN repair than after plate fixation.

CONCLUSIONS:

TEN fixation of displaced midshaft clavicular fractures allows for a faster functional recovery, higher patient satisfaction, and a more cosmetically satisfactory appearance than plate fixation. The complication rates of both TENs and reconstruction plates were similar.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Bone Nails / Bone Plates / Clavicle / Fractures, Bone / Fracture Fixation, Internal Type of study: Diagnostic_studies / Observational_studies / Risk_factors_studies Limits: Adult / Female / Humans / Male / Middle aged Language: En Journal: J Shoulder Elbow Surg Journal subject: ORTOPEDIA Year: 2012 Document type: Article Affiliation country: China

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Bone Nails / Bone Plates / Clavicle / Fractures, Bone / Fracture Fixation, Internal Type of study: Diagnostic_studies / Observational_studies / Risk_factors_studies Limits: Adult / Female / Humans / Male / Middle aged Language: En Journal: J Shoulder Elbow Surg Journal subject: ORTOPEDIA Year: 2012 Document type: Article Affiliation country: China