Your browser doesn't support javascript.
loading
Case study thoracic radiotherapy in an elderly patient with pacemaker: the issue of pacing leads.
Kirova, Youlia M; Menard, Jean; Chargari, Cyrus; Mazal, Alejandro; Kirov, Krassen.
Affiliation
  • Kirova YM; Department of Radiation Oncology, Institut Curie, Paris, France. youlia.kirova@curie.net
Med Dosim ; 37(2): 192-4, 2012.
Article in En | MEDLINE | ID: mdl-22209162
To assess clinical outcome of patients with pacemaker treated with thoracic radiation therapy for T8-T9 paravertebral chloroma. A 92-year-old male patient with chloroma presenting as paravertebral painful and compressive (T8-T9) mass was referred for radiotherapy in the Department of Radiation Oncology, Institut Curie. The patient presented with cardiac dysfunction and a permanent pacemaker that had been implanted prior. The decision of Multidisciplinary Meeting was to deliver 30 Gy in 10 fractions for reducing the symptoms and controlling the tumor growth. The patient received a total dose of 30 Gy in 10 fractions using 4-field conformal radiotherapy with 20-MV photons. The dose to pacemaker was 0.1 Gy but a part of the pacing leads was in the irradiation fields. The patient was treated the first time in the presence of his radiation oncologist and an intensive care unit doctor. Moreover, the function of his pacemaker was monitored during the entire radiotherapy course. No change in pacemaker function was observed during any of the radiotherapy fractions. The radiotherapy was very well tolerated without any side effects. The function of the pacemaker was checked before and after the radiotherapy treatment by the cardiologist and no pacemaker dysfunction was observed. Although updated guidelines are needed with acceptable dose criteria for implantable cardiac devices, it is possible to treat patients with these devices and parts encroaching on the radiation field. This case report shows we were able to safely treat our patient through a multidisciplinary approach, monitoring the patient during each step of the treatment.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Pacemaker, Artificial / Thoracic Neoplasms / Sarcoma, Myeloid Type of study: Guideline / Prognostic_studies Limits: Aged80 / Humans / Male Language: En Journal: Med Dosim Journal subject: RADIOTERAPIA Year: 2012 Document type: Article Affiliation country: France Country of publication: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Pacemaker, Artificial / Thoracic Neoplasms / Sarcoma, Myeloid Type of study: Guideline / Prognostic_studies Limits: Aged80 / Humans / Male Language: En Journal: Med Dosim Journal subject: RADIOTERAPIA Year: 2012 Document type: Article Affiliation country: France Country of publication: United States