Your browser doesn't support javascript.
loading
Carbon dioxide-contrasted computed tomography angiography: high pitch protocols and adapted injection parameters improve imaging quality.
Penzkofer, T; Slebocki, K; Grommes, J; Bruners, P; Isfort, P P; Heussen, N; Schmitz-Rode, T; Kuhl, C K; Langer, S; Mahnken, A H.
Affiliation
  • Penzkofer T; Department of Diagnostic and Interventional Radiology, RWTH Aachen University Hospital, Aachen, Germany.
Rofo ; 185(2): 128-35, 2013 Feb.
Article in En | MEDLINE | ID: mdl-23196833
PURPOSE: To systematically investigate the impact of image acquisition and contrast injection parameters for CO2-enhanced CT angiography (CTA) of the aorto-iliac and peripheral arteries in a pig model using commercially available equipment. The aim was to establish an imaging protocol that is ready for use in human subjects. MATERIALS AND METHODS: Three domestic swine underwent CO2-CTA with varying injection parameters: pitch (1.0, 3.0), injection pressure (0.7 bar, 1.0 bar, 1.3 bar) and scan delay (2 s, 4 s, 6 s). Objective (vessel diameter) and subjective (image quality) parameters and applied radiation doses were systematically evaluated. To ensure clinical applicability of the setting, only approved catheters/injectors and standard injection parameters were evaluated. RESULTS: The image quality scores were superior and the vessel diameter was larger with high pitch in comparison to standard pitch (diameters: 4.7 ± 2.0 mm vs. 3.6 ± 2.1 mm, p = 0.0040, scores: 2.6 ± 1.1 vs. 2.0 ± 1.1, p = 0.0038). High injection pressure (1.3 bar) improved the image quality as assessed by subjective and objective ratings (diameters: 3.6 ± 2.0 mm, 4.0 ± 2.1 mm and 4.6 ± 2.1 mm, for 0.7, 1.0 and 1.3 bar, p-values ≤ 0.0052, scores: 1.9 ± 1.1, 2.3 ± 1.1 and 2.7 ± 1.2, p-values ≤ 0.0017), the same was observed for a shorter injection delay (diameters: 3.5 ± 2.0 mm, 4.2 ± 2.1 mm and 4.8 ± 2.1 mm, for 6 s, 4 s, and 2 s, p ≤ 0.0022, scores: 1.9 ± 1.1, 2.3 ± 1.1 and 2.7 ± 1.1, p-values ≤ 0.0013). The dose length products were 239 ± 47 mGycm (high pitch) and 565 ± 63 mGycm (standard pitch, p-values < 0.0001). CONCLUSION: A higher pitch, shorter delay and higher injection pressure improve image quality in CO2-enhanced CTA. Since commercially available, clinically approved equipment was used. The protocol is now ready for use in human subjects.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Carbon Dioxide / Angiography / Radiographic Image Enhancement / Tomography, X-Ray Computed / Contrast Media Type of study: Diagnostic_studies / Guideline / Prognostic_studies Limits: Animals Language: En Journal: Rofo Year: 2013 Document type: Article Affiliation country: Germany Country of publication: Germany

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Carbon Dioxide / Angiography / Radiographic Image Enhancement / Tomography, X-Ray Computed / Contrast Media Type of study: Diagnostic_studies / Guideline / Prognostic_studies Limits: Animals Language: En Journal: Rofo Year: 2013 Document type: Article Affiliation country: Germany Country of publication: Germany