Your browser doesn't support javascript.
loading
Novel intraoperative evaluation for mitral valve regurgitation: retrograde cardioprotective beating test.
Tachibana, Kazutoshi; Higami, Tetsuya; Miyaki, Yasuko; Takagi, Nobuyuki.
Affiliation
  • Tachibana K; Department of Cardiovascular Surgery, Sapporo Medical University School of Medicine, Sapporo, Japan. aad72150@pop17.odn.ne.jp
Eur J Cardiothorac Surg ; 44(2): 375-6, 2013 Aug.
Article in En | MEDLINE | ID: mdl-23315958
ABSTRACT
In mitral valvuloplasty, the saline injection test is commonly employed. However, discrepancies in regurgitation between the naked eye findings during the saline injection test and the postoperative echocardiographical findings are noted. Here, we describe a technique that allows direct transatrial evaluation of the valve in the fully loaded, beating heart without the risks of air embolism. Physiological systolic mitral valve movement is reproduced under aortic cross-clamping. This novel evaluation enables a complete and safe mitral valve repair.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Systole / Monitoring, Intraoperative / Mitral Valve / Mitral Valve Insufficiency Limits: Humans Language: En Journal: Eur J Cardiothorac Surg Journal subject: CARDIOLOGIA Year: 2013 Document type: Article Affiliation country: Japan

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Systole / Monitoring, Intraoperative / Mitral Valve / Mitral Valve Insufficiency Limits: Humans Language: En Journal: Eur J Cardiothorac Surg Journal subject: CARDIOLOGIA Year: 2013 Document type: Article Affiliation country: Japan