Cleaning up the masses: exclusion lists to reduce contamination with HPLC-MS/MS.
J Proteomics
; 88: 92-103, 2013 Aug 02.
Article
in En
| MEDLINE
| ID: mdl-23501838
Mass spectrometry, in the past five years, has increased in speed, accuracy and use. With the ability of the mass spectrometers to identify increasing numbers of proteins the identification of undesirable peptides (those not from the protein sample) has also increased. Most undesirable contaminants originate in the laboratory and come from either the user (e.g. keratin from hair and skin), or from reagents (e.g. trypsin), that are required to prepare samples for analysis. We found that a significant amount of MS instrument time was spent sequencing peptides from abundant contaminant proteins. While completely eliminating non-specific protein contamination is not feasible, it is possible to reduce the sequencing of these contaminants. For example, exclusion lists can provide a list of masses that can be used to instruct the mass spectrometer to 'ignore' the undesired contaminant peptides in the list. We empirically generated be-spoke exclusion lists for several model organisms (Homo sapiens, Caenorhabditis elegans, Saccharomyces cerevisiae and Xenopus laevis), utilising information from over 500 mass spectrometry runs and cumulative analysis of these data. Here we show that by employing these empirically generated lists, it was possible to reduce the time spent analysing contaminating peptides in a given sample thereby facilitating more efficient data acquisition and analysis. BIOLOGICAL SIGNIFICANCE: Given the current efficacy of the Mass Spectrometry instrumentation, the utilisation of data from ~500 mass spec runs to generate be-spoke exclusion lists and optimise data acquisition is the significance of this manuscript.
Key words
ACN; BSA; CID; Contamination; Data analysis; Exclusion list; HPLC-MS/MS; IP; MRM; MS; MS optimisation; PEG; PTM; SILAC; SRM; acetonitrile; bovine serum albumin; collision induced dissociation; high pressure liquid chromatography-tandem mass spectrometry; immuno-precipitation; m/z; mass spectrometry; mass-to-charge ratio; multiple reaction monitoring; polyethylene glycol; post translation modification; selective reaction monitoring; stable isotope labelling by amino acids in cell culture
Full text:
1
Collection:
01-internacional
Database:
MEDLINE
Main subject:
Peptides
/
Mass Spectrometry
/
Xenopus Proteins
/
Saccharomyces cerevisiae Proteins
/
Caenorhabditis elegans Proteins
/
Proteomics
Limits:
Animals
/
Humans
Language:
En
Journal:
J Proteomics
Journal subject:
BIOQUIMICA
Year:
2013
Document type:
Article
Affiliation country:
United kingdom
Country of publication:
Netherlands