Hardware and software modifications on the Advion NanoTek microfluidic platform to extend flexibility for radiochemical synthesis.
Pascali, Giancarlo; Berton, Andrea; DeSimone, Mariarosaria; Wyatt, Naomi; Matesic, Lidia; Greguric, Ivan; Salvadori, Piero A.
Affiliation
  • Pascali G; LifeSciences Division, Australian Nuclear Science and Technology Organization, New Illawarra Road, Lucas Heights, NSW 2234, Australia; Institute of Clinical Physiology, National Research Council, Via Moruzzi 1, 56124 Pisa, Italy. Electronic address: gianp@ansto.gov.au.
  • Berton A; Institute of Clinical Physiology, National Research Council, Via Moruzzi 1, 56124 Pisa, Italy.
  • DeSimone M; Institute of Clinical Physiology, National Research Council, Via Moruzzi 1, 56124 Pisa, Italy.
  • Wyatt N; LifeSciences Division, Australian Nuclear Science and Technology Organization, New Illawarra Road, Lucas Heights, NSW 2234, Australia.
  • Matesic L; LifeSciences Division, Australian Nuclear Science and Technology Organization, New Illawarra Road, Lucas Heights, NSW 2234, Australia.
  • Greguric I; LifeSciences Division, Australian Nuclear Science and Technology Organization, New Illawarra Road, Lucas Heights, NSW 2234, Australia.
  • Salvadori PA; Institute of Clinical Physiology, National Research Council, Via Moruzzi 1, 56124 Pisa, Italy.
Appl Radiat Isot ; 84: 40-7, 2014 Feb.
Article in En | MEDLINE | ID: mdl-24296158
Microfluidic systems are currently receiving a lot of attention in the PET radiochemistry field, due to their demonstrated ability to obtain higher incorporation yields with reduced total processing time and using a decreased amount of precursors. The Advion NanoTek LF was the first commercial microfluidic system available for radiochemistry that allows basic parameter optimization to be performed. In this paper we report hardware and software modifications that would allow better performing procedures, higher product throughput and flexibility to utilize the system. In particular, HPLC purification and SPE formulation have been fully integrated.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Radiopharmaceuticals / Microfluidic Analytical Techniques / Isotope Labeling Language: En Journal: Appl Radiat Isot Journal subject: MEDICINA NUCLEAR / SAUDE AMBIENTAL Year: 2014 Document type: Article Country of publication: United kingdom

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Radiopharmaceuticals / Microfluidic Analytical Techniques / Isotope Labeling Language: En Journal: Appl Radiat Isot Journal subject: MEDICINA NUCLEAR / SAUDE AMBIENTAL Year: 2014 Document type: Article Country of publication: United kingdom