Clinical biomechanics of instability related to total knee arthroplasty.
Athwal, Kiron K; Hunt, Nicola C; Davies, Andrew J; Deehan, David J; Amis, Andrew A.
Affiliation
  • Athwal KK; Department of Mechanical Engineering, Imperial College London, Exhibition Road, London SW7 2AZ, UK.
  • Hunt NC; Department of Orthopaedic Surgery, Newcastle Freeman University Hospital, Newcastle upon Tyne, UK; Institute of Cellular Medicine, Medical School, Framlington Place Newcastle University, Newcastle upon Tyne NE2 4HH, UK.
  • Davies AJ; Guy's Hospital, Great Maze Pond, London SE1 9RT, UK.
  • Deehan DJ; Department of Orthopaedic Surgery, Newcastle Freeman University Hospital, Newcastle upon Tyne, UK; Institute of Cellular Medicine, Medical School, Framlington Place Newcastle University, Newcastle upon Tyne NE2 4HH, UK.
  • Amis AA; Department of Mechanical Engineering, Imperial College London, Exhibition Road, London SW7 2AZ, UK; Orthopaedic Surgery Group, Imperial College London School of Medicine, Charing Cross Hospital, London W6 8RF, UK. Electronic address: a.amis@imperial.ac.uk.
Clin Biomech (Bristol, Avon) ; 29(2): 119-28, 2014 Feb.
Article in En | MEDLINE | ID: mdl-24332382
ABSTRACT

BACKGROUND:

Tibiofemoral instability is a common reason for total knee arthroplasty failure, and may be attributed to soft tissue deficiency and incorrect ligament balancing. There are many different designs of implant with varying levels of constraint to overcome this instability; however there is little advice for surgeons to assess which is suitable for a specific patient, and soft tissue balance testing during arthroplasty is very subjective.

METHOD:

The current theories on primary and secondary soft tissue restraints to anterior/posterior, varus/valgus, and internal/external rotational motion of the knee are discussed. The paper reviews biomechanics literature to evaluate instability in the intact and implanted knee.

FINDINGS:

The paper highlights important intra- and extra-capsular structures in the knee and describes the techniques used by clinicians to assess instability perioperatively. In vitro cadaveric studies were found to be a very useful tool in comparing different implants and contributions of different soft tissues.

INTERPRETATION:

In vitro cadaveric studies can be utilised in helping less experienced surgeons with soft tissue releases and determining the correct implant. For this to happen, more biomechanical studies must be done to show the impact of release sequences on implanted cadavers, as well as determining if increasingly constrained implants restore the stability of the knee to pre-deficient conditions.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Prosthesis Design / Arthroplasty, Replacement, Knee / Joint Instability / Knee Joint / Knee Prosthesis Type of study: Diagnostic_studies / Etiology_studies Limits: Humans Language: En Journal: Clin Biomech (Bristol, Avon) Journal subject: ENGENHARIA BIOMEDICA / FISIOLOGIA Year: 2014 Document type: Article Affiliation country: United kingdom

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Prosthesis Design / Arthroplasty, Replacement, Knee / Joint Instability / Knee Joint / Knee Prosthesis Type of study: Diagnostic_studies / Etiology_studies Limits: Humans Language: En Journal: Clin Biomech (Bristol, Avon) Journal subject: ENGENHARIA BIOMEDICA / FISIOLOGIA Year: 2014 Document type: Article Affiliation country: United kingdom